NYFGY 3,6/6 kV, acc. to DIN VDE 0271
NYFGY 3,6/6 kV, acc. to DIN VDE 0271
Three-core PVC-insulated copper cables with galvanized flat steel wire armouring
Read moreNYFGY 3,6/6 kV, acc. to DIN VDE 0271
Product ref. 22303025
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Conductor cross-section: 25 mm²
- Minimum outer diameter: 33.0 mm
- Maximum outer diameter: 42.0 mm
- Approximate weight: 2200 kg/km
- Nominal outer sheath thickness: 2.0 mm
- Permissible current rating in open air: 105 A
- Permissible current rating when buried: 129 A
NYFGY 3,6/6 kV, acc. to DIN VDE 0271
Product ref. 22303035
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Conductor cross-section: 35 mm²
- Minimum outer diameter: 36.0 mm
- Maximum outer diameter: 43.0 mm
- Approximate weight: 2530 kg/km
- Nominal outer sheath thickness: 2.1 mm
- Permissible current rating in open air: 128 A
- Permissible current rating when buried: 155 A
NYFGY 3,6/6 kV, acc. to DIN VDE 0271
Product ref. 22303050
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Conductor cross-section: 50 mm²
- Minimum outer diameter: 39.6 mm
- Maximum outer diameter: 46.0 mm
- Approximate weight: 2989 kg/km
- Nominal outer sheath thickness: 2.2 mm
- Permissible current rating in open air: 155 A
- Permissible current rating when buried: 184 A
NYFGY 3,6/6 kV, acc. to DIN VDE 0271
Product ref. 22303070
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Conductor cross-section: 70 mm²
- Minimum outer diameter: 43.1 mm
- Maximum outer diameter: 49.0 mm
- Approximate weight: 3768 kg/km
- Nominal outer sheath thickness: 2.3 mm
- Permissible current rating in open air: 196 A
- Permissible current rating when buried: 227 A
NYFGY 3,6/6 kV, acc. to DIN VDE 0271
Product ref. 22303095
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Conductor cross-section: 95 mm²
- Minimum outer diameter: 46.0 mm
- Maximum outer diameter: 53.0 mm
- Approximate weight: 4700 kg/km
- Nominal outer sheath thickness: 2.4 mm
- Permissible current rating in open air: 242 A
- Permissible current rating when buried: 272 A
NYFGY 3,6/6 kV, acc. to DIN VDE 0271
Product ref. 22303120
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Conductor cross-section: 120 mm²
- Minimum outer diameter: 49.1 mm
- Maximum outer diameter: 56.0 mm
- Approximate weight: 5527 kg/km
- Nominal outer sheath thickness: 2.6 mm
- Permissible current rating in open air: 280 A
- Permissible current rating when buried: 309 A
NYFGY 3,6/6 kV, acc. to DIN VDE 0271
Product ref. 22303150
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Conductor cross-section: 150 mm²
- Minimum outer diameter: 52.3 mm
- Maximum outer diameter: 59.0 mm
- Approximate weight: 6505 kg/km
- Nominal outer sheath thickness: 2.7 mm
- Permissible current rating in open air: 319 A
- Permissible current rating when buried: 346 A
NYFGY 3,6/6 kV, acc. to DIN VDE 0271
Product ref. 22303185
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Conductor cross-section: 185 mm²
- Minimum outer diameter: 55.8 mm
- Maximum outer diameter: 64.0 mm
- Approximate weight: 7751 kg/km
- Nominal outer sheath thickness: 2.8 mm
- Permissible current rating in open air: 366 A
- Permissible current rating when buried: 390 A
NYFGY 3,6/6 kV, acc. to DIN VDE 0271
Product ref. 22303240
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Conductor cross-section: 240 mm²
- Minimum outer diameter: 60.2 mm
- Maximum outer diameter: 68.0 mm
- Approximate weight: 9555 kg/km
- Nominal outer sheath thickness: 2.9 mm
- Permissible current rating in open air: 430 A
- Permissible current rating when buried: 449 A
NYFGY 3,6/6 kV, acc. to DIN VDE 0271
Product ref. 22303300
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Conductor cross-section: 300 mm²
- Minimum outer diameter: 64.4 mm
- Maximum outer diameter: 71.0 mm
- Approximate weight: 11500 kg/km
- Nominal outer sheath thickness: 3.0 mm
- Permissible current rating in open air: 497 A
- Permissible current rating when buried: 480 A
Description
Description
Standards
-
ProductDIN VDE 0271
Application
Installation in ground, outdoors, in water, indoors and in cable ducts if greater mechanical protection is required or if greater tensile stresses are to be expected during installation and operation.
Construction
Conductor: stranded copper wires
Insulation: PVC (polyvinyl chloride)
Inner covering: extruded or lapped
Armour: galvanized flat steel wires and counter helix of galvanized steel tape
Outer sheath: PVC (polyvinyl chloride); Colour: red
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Selling & delivery Information
Marking on the outer sheath acc. to DIN VDE