TCX® ( C ) 331 150/250V 4x3x1.5

Description

Description

Standards

  • Product
    IEC 60228
  • Installation
    IEC 60092-350; IEC 60092-351; IEC 60092-359; IEC 60092-376
  • Test
    IEC 60331; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034

Application

TCX® (C) 331 type is used on board of ships in all locationsfor installations complying with IEC standards 60092-352. For open deck installation, cables have to be coveredagainst UV rays. TCX® (C) 331 type meets IEC 60331fire resistant performances, withstands IEC 60332-3-22 fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire.

 

Design

 

  1. Conductor:
    Bare copper
    Stranded class 2

  2. Insulation:
    Mica tape + XLPE

  3. Inner covering:
    Polyester tape lapped

  4. Armouring:
    Bare copper braid with bare copper drain wire

  5. Outer sheath:
    Polyolefin
    Colour: orange

 

 

*Note: 2 pairs assembled as a quad

 

Core Identification

Core 1: white + printed number
Core 2: blue + printed number
Core 3: red + printed number

 

Marking

NEXANS 448 TCX (C) 331* «voltage» «n» x 2 «or» 3 x «s» mm2 90C IEC 60332-3-22 IEC 60331 "WW/YY" * CE *  + Metric marking

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Bare copper
Conductor flexibility
Stranded class 2
Insulation
XLPE + Mica tape
Outer sheath
Polyolefin
Halogen free
IEC 60754-1
Sheath colour
Orange
Armour type
Bare copper braid
Drain wire
Bare copper
Protection
Polyester tape(s)

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
1.5 mm²
Number of pairs
-
Number of triples
4
Minimum outer diameter
18.5 mm
Nominal outer diameter
20.7 mm
Maximum outer diameter
23.5 mm
Approximate weight
500 kg/km

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
150 / 250 (300) V
Max. DC resistance of the conductor at 20°C
25.6 Ohm/km

Usage characteristics

Usage characteristics

Standard
IEC
Fire retardant
EN IEC 60332-3-22 (cat A)
Smoke density
IEC 61034
Gases corrosivity
IEC 60754-2
Electro magnetic interference resistance
Yes
Max. conductor temperature in service
90 °C
Midspan
-
Operating temperature, range
-30 ... 80 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close