MPRXCX EMC 0.6/1kV 3x16
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 16 mm²
- Approximate weight: 1121 kg/km
- Maximum outer diameter: 29.2 mm
- Permissible current rating in open air: 67 A
MPRXCX EMC 0.6/1kV 3x16+3x6E
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 16 mm²
- Approximate weight: 1231 kg/km
- Maximum outer diameter: 29.2 mm
- Permissible current rating in open air: 67 A
MPRXCX EMC 0.6/1kV 3x16+1x16E
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 16 mm²
- Approximate weight: 1394 kg/km
- Maximum outer diameter: 32.2 mm
- Permissible current rating in open air: 67 A
MPRXCX EMC 0.6/1kV 3x25
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 25 mm²
- Approximate weight: 1450 kg/km
- Maximum outer diameter: 32.0 mm
- Permissible current rating in open air: 89 A
MPRXCX EMC 0.6/1kV 3x25+3x6E
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 25 mm²
- Approximate weight: 1568 kg/km
- Maximum outer diameter: 32.0 mm
- Permissible current rating in open air: 89 A
MPRXCX EMC 0.6/1kV 3x25+1x16E
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 25 mm²
- Approximate weight: 1760 kg/km
- Maximum outer diameter: 35.3 mm
- Permissible current rating in open air: 89 A
MPRXCX EMC 0.6/1kV 3x35
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 35 mm²
- Approximate weight: 1835 kg/km
- Maximum outer diameter: 35.0 mm
- Permissible current rating in open air: 110 A
MPRXCX EMC 0.6/1kV 3x35+3x10E
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 35 mm²
- Approximate weight: 2023 kg/km
- Maximum outer diameter: 35.0 mm
- Permissible current rating in open air: 110 A
MPRXCX EMC 0.6/1kV 3x35+1x25E
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 35 mm²
- Approximate weight: 2245 kg/km
- Maximum outer diameter: 39.0 mm
- Permissible current rating in open air: 110 A
MPRXCX EMC 0.6/1kV 3x50
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 50 mm²
- Approximate weight: 2409 kg/km
- Maximum outer diameter: 39.1 mm
- Permissible current rating in open air: 137 A
MPRXCX EMC 0.6/1kV 3x50+3x10E
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 50 mm²
- Approximate weight: 2587 kg/km
- Maximum outer diameter: 39.1 mm
- Permissible current rating in open air: 137 A
MPRXCX EMC 0.6/1kV 3x50+1x25E
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 50 mm²
- Approximate weight: 2961 kg/km
- Maximum outer diameter: 43.0 mm
- Permissible current rating in open air: 137 A
MPRXCX EMC 0.6/1kV 3x70
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 70 mm²
- Approximate weight: 3157 kg/km
- Maximum outer diameter: 44.0 mm
- Permissible current rating in open air: 169 A
MPRXCX EMC 0.6/1kV 3x70+3x16E
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 70 mm²
- Approximate weight: 3436 kg/km
- Maximum outer diameter: 44.0 mm
- Permissible current rating in open air: 169 A
MPRXCX EMC 0.6/1kV 3x70+1x35E
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 70 mm²
- Approximate weight: 3839 kg/km
- Maximum outer diameter: 49.0 mm
- Permissible current rating in open air: 169 A
MPRXCX EMC 0.6/1kV 3x95
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 95 mm²
- Approximate weight: 4070 kg/km
- Maximum outer diameter: 49.3 mm
- Permissible current rating in open air: 205 A
MPRXCX EMC 0.6/1kV 3x95+3x25E
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 95 mm²
- Approximate weight: 4575 kg/km
- Maximum outer diameter: 49.3 mm
- Permissible current rating in open air: 205 A
MPRXCX EMC 0.6/1kV 3x95+1x50E
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 95 mm²
- Approximate weight: 4910 kg/km
- Maximum outer diameter: 54.7 mm
- Permissible current rating in open air: 205 A
MPRXCX EMC 0.6/1kV 3x120
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 120 mm²
- Approximate weight: 5090 kg/km
- Maximum outer diameter: 53.5 mm
- Permissible current rating in open air: 237 A
MPRXCX EMC 0.6/1kV 3x120+3x25E
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 120 mm²
- Approximate weight: 5536 kg/km
- Maximum outer diameter: 53.5 mm
- Permissible current rating in open air: 237 A
MPRXCX EMC 0.6/1kV 3x120+1x70E
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 120 mm²
- Approximate weight: 6074 kg/km
- Maximum outer diameter: 58.5 mm
- Permissible current rating in open air: 237 A
MPRXCX EMC 0.6/1kV 3x150
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 150 mm²
- Approximate weight: 6320 kg/km
- Maximum outer diameter: 57.4 mm
- Permissible current rating in open air: 273 A
MPRXCX EMC 0.6/1kV 3x150+3x35E
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 150 mm²
- Approximate weight: 6642 kg/km
- Maximum outer diameter: 57.4 mm
- Permissible current rating in open air: 273 A
MPRXCX EMC 0.6/1kV 3x150+1x95E
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 150 mm²
- Approximate weight: 7271 kg/km
- Maximum outer diameter: 63.2 mm
- Permissible current rating in open air: 273 A
Description
Description
Standards
-
ProductIEC 60228
-
InstallationIEC 60092-350; IEC 60092-351; IEC 60092-353; IEC 60092-359
-
TestIEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Application
Motor supply cable for frequency converters controlled low voltage AC drives on ships board. These MPRXCX EMC cables are shielded with 100% coverage copper Polyester tape which to ensure a high EMC protection. MPRXCX EMC type withstands IEC60332-3-22 fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire.
Design
- Conductor:
Stranded bare copper
Class 2 - Insulation:
XLPE (cross linked polyethylene) - Inner covering:
(Filler if necessary)
Lapped or extruded - Screen / Armouring:
Copper / Polyester tape
Bare copper braid - Outer sheath:
Polyolefin SHF1 (SHF2 on request)
Colour: black
Core Identification
3 cores: Black- White-Brown
Earth core:Green/Yellow
Marking
NEXANS 448 MPRXCX EMC «voltage» «n» x «s» mm2 90C IEC 60332-3-22 «WW/YY» * CE * + Metric Marking
Characteristics
Characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania