MPRXCX® EMC 0.6/1kV

Products

MPRXCX EMC 0.6/1kV 3x16

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 16 mm²
  • Approximate weight: 1121 kg/km
  • Maximum outer diameter: 29.2 mm
  • Permissible current rating in open air: 67 A

 

MPRXCX EMC 0.6/1kV 3x16+3x6E

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 16 mm²
  • Approximate weight: 1231 kg/km
  • Maximum outer diameter: 29.2 mm
  • Permissible current rating in open air: 67 A

 

MPRXCX EMC 0.6/1kV 3x16+1x16E

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 16 mm²
  • Approximate weight: 1394 kg/km
  • Maximum outer diameter: 32.2 mm
  • Permissible current rating in open air: 67 A

 

MPRXCX EMC 0.6/1kV 3x25

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 25 mm²
  • Approximate weight: 1450 kg/km
  • Maximum outer diameter: 32.0 mm
  • Permissible current rating in open air: 89 A

 

MPRXCX EMC 0.6/1kV 3x25+3x6E

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 25 mm²
  • Approximate weight: 1568 kg/km
  • Maximum outer diameter: 32.0 mm
  • Permissible current rating in open air: 89 A

 

MPRXCX EMC 0.6/1kV 3x25+1x16E

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 25 mm²
  • Approximate weight: 1760 kg/km
  • Maximum outer diameter: 35.3 mm
  • Permissible current rating in open air: 89 A

 

MPRXCX EMC 0.6/1kV 3x35

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 35 mm²
  • Approximate weight: 1835 kg/km
  • Maximum outer diameter: 35.0 mm
  • Permissible current rating in open air: 110 A

 

MPRXCX EMC 0.6/1kV 3x35+3x10E

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 35 mm²
  • Approximate weight: 2023 kg/km
  • Maximum outer diameter: 35.0 mm
  • Permissible current rating in open air: 110 A

 

MPRXCX EMC 0.6/1kV 3x35+1x25E

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 35 mm²
  • Approximate weight: 2245 kg/km
  • Maximum outer diameter: 39.0 mm
  • Permissible current rating in open air: 110 A

 

MPRXCX EMC 0.6/1kV 3x50

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 50 mm²
  • Approximate weight: 2409 kg/km
  • Maximum outer diameter: 39.1 mm
  • Permissible current rating in open air: 137 A

 

MPRXCX EMC 0.6/1kV 3x50+3x10E

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 50 mm²
  • Approximate weight: 2587 kg/km
  • Maximum outer diameter: 39.1 mm
  • Permissible current rating in open air: 137 A

 

MPRXCX EMC 0.6/1kV 3x50+1x25E

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 50 mm²
  • Approximate weight: 2961 kg/km
  • Maximum outer diameter: 43.0 mm
  • Permissible current rating in open air: 137 A

 

MPRXCX EMC 0.6/1kV 3x70

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 70 mm²
  • Approximate weight: 3157 kg/km
  • Maximum outer diameter: 44.0 mm
  • Permissible current rating in open air: 169 A

 

MPRXCX EMC 0.6/1kV 3x70+3x16E

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 70 mm²
  • Approximate weight: 3436 kg/km
  • Maximum outer diameter: 44.0 mm
  • Permissible current rating in open air: 169 A

 

MPRXCX EMC 0.6/1kV 3x70+1x35E

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 70 mm²
  • Approximate weight: 3839 kg/km
  • Maximum outer diameter: 49.0 mm
  • Permissible current rating in open air: 169 A

 

MPRXCX EMC 0.6/1kV 3x95

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²
  • Approximate weight: 4070 kg/km
  • Maximum outer diameter: 49.3 mm
  • Permissible current rating in open air: 205 A

 

MPRXCX EMC 0.6/1kV 3x95+3x25E

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²
  • Approximate weight: 4575 kg/km
  • Maximum outer diameter: 49.3 mm
  • Permissible current rating in open air: 205 A

 

MPRXCX EMC 0.6/1kV 3x95+1x50E

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²
  • Approximate weight: 4910 kg/km
  • Maximum outer diameter: 54.7 mm
  • Permissible current rating in open air: 205 A

 

MPRXCX EMC 0.6/1kV 3x120

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 120 mm²
  • Approximate weight: 5090 kg/km
  • Maximum outer diameter: 53.5 mm
  • Permissible current rating in open air: 237 A

 

MPRXCX EMC 0.6/1kV 3x120+3x25E

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 120 mm²
  • Approximate weight: 5536 kg/km
  • Maximum outer diameter: 53.5 mm
  • Permissible current rating in open air: 237 A

 

MPRXCX EMC 0.6/1kV 3x120+1x70E

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 120 mm²
  • Approximate weight: 6074 kg/km
  • Maximum outer diameter: 58.5 mm
  • Permissible current rating in open air: 237 A

 

MPRXCX EMC 0.6/1kV 3x150

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Approximate weight: 6320 kg/km
  • Maximum outer diameter: 57.4 mm
  • Permissible current rating in open air: 273 A

 

MPRXCX EMC 0.6/1kV 3x150+3x35E

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Approximate weight: 6642 kg/km
  • Maximum outer diameter: 57.4 mm
  • Permissible current rating in open air: 273 A

 

MPRXCX EMC 0.6/1kV 3x150+1x95E

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Approximate weight: 7271 kg/km
  • Maximum outer diameter: 63.2 mm
  • Permissible current rating in open air: 273 A

 

Description

Description

Standards

  • Product
    IEC 60228
  • Installation
    IEC 60092-350; IEC 60092-351; IEC 60092-353; IEC 60092-359
  • Test
    IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034

Application

Motor supply cable for frequency converters controlled low voltage AC drives on ships board. These MPRXCX EMC cables are shielded with 100% coverage copper Polyester tape which to ensure a high EMC protection. MPRXCX EMC type withstands IEC60332-3-22 fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire.

Design

  1. Conductor:
    Stranded bare copper
    Class 2
  2. Insulation:
    XLPE (cross linked polyethylene)
  3. Inner covering:
    (Filler if necessary)
     
    Lapped or extruded
  4. Screen / Armouring:
    Copper / Polyester tape
    Bare copper braid
  5. Outer sheath:
    Polyolefin SHF1 (SHF2 on request)
    Colour: black

 

Core Identification

3 cores: Black- White-Brown

Earth core:Green/Yellow

 

Marking

NEXANS 448 MPRXCX EMC «voltage» «n» x «s» mm2 90C IEC 60332-3-22 «WW/YY» * CE * + Metric Marking

Characteristics

Characteristics

Usage characteristics

Usage characteristics

Fire retardant
-
Gases corrosivity
IEC 60754-2
Max. conductor temperature in service
90 °C
Operating temperature, range
-30 ... 80 °C
Electro magnetic interference resistance
Yes
Smoke density
IEC 61034

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close