Description
Description
Standards
-
ProductIEC 60228
-
InstallationIEC 60092-350; IEC 60092-351; IEC 60092-353; IEC 60092-359
-
TestIEC 60331-1 or 2; IEC 60331; IEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Application
MPRXCX® 331 type is used on board of ships at all levels and open decks for fixed installations complying with IEC standards 60092-352 and in safety circuits, where fire resistance is required. The good screening qualities of the braid also reduce radio interference and electrical influences to electronic installations. MPRXCX® 331 type meets the IEC 60331 fire characteristics, withstands IEC 60332-3-22 fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire.
Design
- Conductor
Stranded Bare copper class 2
- Insulation
Mica tape + XLPE
- Inner covering
Extruded
- Armouring
Bare copper braid
- Outer sheath
Polyolefin SHF1 (SHF2 on request)
Colour :black
Core Identification
1 core: black
2 cores: black-blue
3 cores: black-white-brown or black-blue-green/yellow
4 cores: black-white-brown-blue or green/yellow
5 cores and above: white with black printed numbers
Marking
NEXANS 448 MPRXCX 331 «voltage» «n» x «s» mm2 90C IEC 60332-3-22 IEC 60331 «WW/YY» * CE * + Metric Marking
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania