Descripción
Descripción
Estándares
-
ProductIEC 60228
-
InstallationIEC 60092-350; IEC 60092-351; IEC 60092-353; IEC 60092-359
-
TestIEC 60331-1 or 2; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Application
MPRX® 331 type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards 60092-352 and in safety circuits, where fire resistance is required. MPRX® 331 type meets the IEC 60331 fire resistant performances, withstands IEC 60332-3- 22 fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free.
Design
1. Conductor:
Bare copper Stranded class 2
2. Insulation:
Mica Tape + XLPE (cross linked polyethylene)
3. Outer sheath:
(Filler if necessary)
Polyolefin SHF1 (SHF2 on request)
Colour: black
Core Identification
1 core: black
2 cores: black-blue
3 cores: black-white-brown or black-blue-green/yellow
4 cores: black-white-brown-blue- or green/yellow
5 cores and above: white with black printed numbers
Marking
NEXANS 448 MPRX 331 0.6/1kV «n» x «s» 90C IEC 60332-3-22 «WW/YY» * CE * + Metric Marking