ENERGYFLEX WATER RESISTANT
ENERGYFLEX WATER RESISTANT
Outstanding water proof performance
The ENERGYFLEX® WR patented solar cable is designed to withstand humid or immersed installations over its lifetime.
ENERGYFLEX WR 1x10² 1.5kV DC NUOVO
Rif. Lynxeo
- Imballo: Bobina
- Sezione del conduttore del cavo: 10 mm²
- Nominal conductor diameter: 4 mm
- Peso approssimativo del cavo: 140 kg/km
- Massima resistenza el. del cond. a 20°C in c.c.: 3,39 Ohm/km
- Permissible current rating in air 60°C: 98 A
- Permissible current rating on a tray 60°C: 93 A
- Corrente di corto circuito nel conduttore 1s: 1,4 kA
ENERGYFLEX WR 1x4² 1.5kV DC NUOVO
Rif. Lynxeo
- Imballo: Bobina
- Sezione del conduttore del cavo: 4 mm²
- Nominal conductor diameter: 2,5 mm
- Peso approssimativo del cavo: 77 kg/km
- Massima resistenza el. del cond. a 20°C in c.c.: 5,09 Ohm/km
- Permissible current rating in air 60°C: 55 A
- Permissible current rating on a tray 60°C: 52 A
- Corrente di corto circuito nel conduttore 1s: 0,5 kA
ENERGYFLEX WR 1x6² 1.5kV DC NUOVO
Rif. Lynxeo
- Imballo: Bobina
- Sezione del conduttore del cavo: 6 mm²
- Nominal conductor diameter: 2,9 mm
- Peso approssimativo del cavo: 95 kg/km
- Massima resistenza el. del cond. a 20°C in c.c.: 5,09 Ohm/km
- Permissible current rating in air 60°C: 50 A
- Permissible current rating on a tray 60°C: 67 A
- Corrente di corto circuito nel conduttore 1s: 0,8 kA
Descrizione
Descrizione
Norme
-
ProductEN 50618; IEC 60228; IEC 62930
DESIGN
Single core water resistant solar cable with low smoke, halogen free, crosslinked insulation and sheath.
1. Conductor
Stranded tinned copper wires class 5 acc. IEC 60228
2. Insulation
Cross-linked halogen-free rubber
Colour: white
3. Sheath
Cross-linked halogen-free fire retardant rubber
Colour: black
Example of marking: ENERGYFLEX® IWR USE < HAR > H1Z2Z2-K 62930 IEC 131 PV1500-WR 1 x S mm² 1.5/1.5 (1,8) kV DC lynxeo 269 HALOGEN FREE LOW SMOKE Dca
FEATURES
ENERGYFLEX® WR cables are dedicated to the photovoltaic system direct current (D.C.) side with a nominal D.C. voltage of 1.5 kV and a maximum D.C. voltage of 1.8 kV. Cable suitable to be used with Class II equipment.
These cables are suitable for permanent outdoor long-term use, under variable and harsh climate conditions. They are designed and tested to operate at a normal maximum conductor temperature of 90°C and for 20,000 hours up to 120°C. Therefore, the expected period use is 30 to 40 years under normal usage conditions (lifetime acc. to Arrhenius Diagram).
ENERGYFLEX® WR cables have been put under testing protocol TÜV 2PfG 2750/09.20 - Requirements for cables with improved water resistance for installation in photovoltaic-systems 84 days (2,016 hours) / 90ºC / 3,6 KV DC (vs 1,8 kV DC at 85°C during 240 hours for IEC 62930 / EN 50618 cables). They are suitable for installations immerged in water for 12 months / year.
LIST OF CERTIFICATES
NF EN 50618: BUREAU VERITAS LCIE licence 662568
IEC 62930: BUREAU VERITAS Certificate of conformity 158416-729944