EN 2767-010 A DR
EN 2767-010 A DR
Designed for general Purpose Aircraft Wiring Applications.
UV Laser printable Wire
260°C Operating Temperature Light Weight
Arc Tracking Resistant
EN 2267-010A 001
Rif. Nexans
- Calibro (AWG): 26
- Maximum core diameter: 0,49 mm
- minimum core diameter: 0,47 mm
- Diametro esterno max: 0,84 mm
- Minimum cable diameter: 0,75 mm
- Conductor stranding: 19 x 0.10
- Peso Massimo: 2,08 g/m
- Nominal weight: 1,95 g/m
- Massima resistenza el. del cond. a 20°C in c.c.: 160 Ohm/km
EN 2267-010A 002
Rif. Nexans
- Calibro (AWG): 24
- Maximum core diameter: 0,58 mm
- minimum core diameter: 0,56 mm
- Diametro esterno max: 0,96 mm
- Minimum cable diameter: 0,85 mm
- Conductor stranding: 19 x 0.12
- Peso Massimo: 2,72 g/m
- Nominal weight: 2,64 g/m
- Massima resistenza el. del cond. a 20°C in c.c.: 114 Ohm/km
EN 2267-010A 004
Rif. Nexans
- Calibro (AWG): 22
- Maximum core diameter: 0,73 mm
- minimum core diameter: 0,71 mm
- Diametro esterno max: 1,1 mm
- Minimum cable diameter: 1 mm
- Conductor stranding: 19 x 0.15
- Peso Massimo: 4,14 g/m
- Nominal weight: 3,89 g/m
- Massima resistenza el. del cond. a 20°C in c.c.: 60 Ohm/km
EN 2267-010A 006
Rif. Nexans
- Calibro (AWG): 20
- Maximum core diameter: 0,97 mm
- minimum core diameter: 0,94 mm
- Diametro esterno max: 1,34 mm
- Minimum cable diameter: 1,22 mm
- Conductor stranding: 19 x 0.20
- Peso Massimo: 6,85 g/m
- Nominal weight: 6,57 g/m
- Massima resistenza el. del cond. a 20°C in c.c.: 32,2 Ohm/km
EN 2267-010A 010
Rif. Nexans
- Calibro (AWG): 16
- Maximum core diameter: 1,22 mm
- minimum core diameter: 1,19 mm
- Diametro esterno max: 1,61 mm
- Minimum cable diameter: 1,46 mm
- Conductor stranding: 19 x 0.25
- Peso Massimo: 10,43 g/m
- Nominal weight: 10,15 g/m
- Massima resistenza el. del cond. a 20°C in c.c.: 21,1 Ohm/km
EN 2267-010A 012
Rif. Nexans
- Calibro (AWG): 18
- Maximum core diameter: 1,45 mm
- minimum core diameter: 1,41 mm
- Diametro esterno max: 1,92 mm
- Minimum cable diameter: 1,76 mm
- Conductor stranding: 19 x 0.30
- Peso Massimo: 14,61 g/m
- Nominal weight: 14,05 g/m
- Massima resistenza el. del cond. a 20°C in c.c.: 14,5 Ohm/km
EN 2267-010A 020
Rif. Nexans
- Calibro (AWG): 14
- Maximum core diameter: 1,73 mm
- minimum core diameter: 1,69 mm
- Diametro esterno max: 2,24 mm
- Minimum cable diameter: 2,04 mm
- Conductor stranding: 37 x 0.25
- Peso Massimo: 19,78 g/m
- Nominal weight: 19,31 g/m
- Massima resistenza el. del cond. a 20°C in c.c.: 10,9 Ohm/km
EN 2267-010A 030
Rif. Nexans
- Calibro (AWG): 12
- Maximum core diameter: 2,18 mm
- minimum core diameter: 2,13 mm
- Diametro esterno max: 2,7 mm
- Minimum cable diameter: 2,5 mm
- Conductor stranding: 37 x 0.32
- Peso Massimo: 31,33 g/m
- Nominal weight: 29,25 g/m
- Massima resistenza el. del cond. a 20°C in c.c.: 6,8 Ohm/km
EN 2267-010A 051
Rif. Nexans
- Calibro (AWG): 10
- Maximum core diameter: 2,77 mm
- minimum core diameter: 2,73 mm
- Diametro esterno max: 3,33 mm
- Minimum cable diameter: 3,13 mm
- Conductor stranding: 61 x 0.32
- Peso Massimo: 49,85 g/m
- Nominal weight: 47,37 g/m
- Massima resistenza el. del cond. a 20°C in c.c.: 4,1 Ohm/km
EN 2267-010A 090
Rif. Nexans
- Calibro (AWG): 8
- Maximum core diameter: 3,85 mm
- minimum core diameter: 3,55 mm
- Diametro esterno max: 4,4 mm
- Minimum cable diameter: 4,1 mm
- Conductor stranding: 127 x 0.30
- Peso Massimo: 90 g/m
- Nominal weight: 87,81 g/m
- Massima resistenza el. del cond. a 20°C in c.c.: 2,3 Ohm/km
EN 2267-010A 140
Rif. Nexans
- Calibro (AWG): 6
- Maximum core diameter: 5,2 mm
- minimum core diameter: 4,8 mm
- Diametro esterno max: 5,7 mm
- Minimum cable diameter: 5,3 mm
- Conductor stranding: 27 x 7 x 0.30
- Peso Massimo: 135 g/m
- Nominal weight: 132,41 g/m
- Massima resistenza el. del cond. a 20°C in c.c.: 1,58 Ohm/km
EN 2267-010A 220
Rif. Nexans
- Calibro (AWG): 4
- Maximum core diameter: 6,8 mm
- minimum core diameter: - mm
- Diametro esterno max: 7,41 mm
- Minimum cable diameter: 6,71 mm
- Conductor stranding: 37 x 12 x 0.25
- Peso Massimo: 222 g/m
- Nominal weight: 215,15 g/m
- Massima resistenza el. del cond. a 20°C in c.c.: 0,97 Ohm/km
EN 2267-010A 340
Rif. Nexans
- Calibro (AWG): 2
- Maximum core diameter: 8,6 mm
- minimum core diameter: - mm
- Diametro esterno max: 9,16 mm
- Minimum cable diameter: 8,28 mm
- Conductor stranding: 37 x 19 x 0.25
- Peso Massimo: 347 g/m
- Nominal weight: 336,1 g/m
- Massima resistenza el. del cond. a 20°C in c.c.: 0,61 Ohm/km
Descrizione
Descrizione
Norme
-
ProductEN 2267-010
Design Construction
1-Core
Stranded Conductor : Nickel Plated High
Strength Copper Alloy (AWG 26 & 24) or
Nickel Plated Copper (AWG 22 to 2)
2-Insulation
Special Polyimide Tape
Special UV PTFE Tape(s)
IDENTIFICATION
Standard colour code :
White except AWG 26 which is light yellow and AWG 22 which is light green
AWG 24 is available in light blue color (EN2267-010A 002B)
Color of marking: green
Marking text: EN DR ** FR F ++
DR = Short designation
** = AWG Wire Size
FR = Country of origin (FR = France)
F = Manufacturer (F = Nexans)
++ = Year of production (i.e. 13 = 2013)
Caratteristiche
Caratteristiche
Caratteristiche elettriche
Caratteristiche elettriche
Caratteristiche d'utilizzo
Caratteristiche d'utilizzo
Risorse
Risorse
I nostri siti web
Seleziona il tuo paese per trovare i nostri prodotti e soluzioni
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania