EN 2767-010 A DR

Prodotti

EN 2267-010A 001

Rif. Nexans

  • Calibro (AWG): 26
  • Maximum core diameter: 0,49 mm
  • minimum core diameter: 0,47 mm
  • Diametro esterno max: 0,84 mm
  • Minimum cable diameter: 0,75 mm
  • Conductor stranding: 19 x 0.10
  • Peso Massimo: 2,08 g/m
  • Nominal weight: 1,95 g/m
  • Massima resistenza el. del cond. a 20°C in c.c.: 160 Ohm/km

 

EN 2267-010A 002

Rif. Nexans

  • Calibro (AWG): 24
  • Maximum core diameter: 0,58 mm
  • minimum core diameter: 0,56 mm
  • Diametro esterno max: 0,96 mm
  • Minimum cable diameter: 0,85 mm
  • Conductor stranding: 19 x 0.12
  • Peso Massimo: 2,72 g/m
  • Nominal weight: 2,64 g/m
  • Massima resistenza el. del cond. a 20°C in c.c.: 114 Ohm/km

 

EN 2267-010A 004

Rif. Nexans

  • Calibro (AWG): 22
  • Maximum core diameter: 0,73 mm
  • minimum core diameter: 0,71 mm
  • Diametro esterno max: 1,1 mm
  • Minimum cable diameter: 1 mm
  • Conductor stranding: 19 x 0.15
  • Peso Massimo: 4,14 g/m
  • Nominal weight: 3,89 g/m
  • Massima resistenza el. del cond. a 20°C in c.c.: 60 Ohm/km

 

EN 2267-010A 006

Rif. Nexans

  • Calibro (AWG): 20
  • Maximum core diameter: 0,97 mm
  • minimum core diameter: 0,94 mm
  • Diametro esterno max: 1,34 mm
  • Minimum cable diameter: 1,22 mm
  • Conductor stranding: 19 x 0.20
  • Peso Massimo: 6,85 g/m
  • Nominal weight: 6,57 g/m
  • Massima resistenza el. del cond. a 20°C in c.c.: 32,2 Ohm/km

 

EN 2267-010A 010

Rif. Nexans

  • Calibro (AWG): 16
  • Maximum core diameter: 1,22 mm
  • minimum core diameter: 1,19 mm
  • Diametro esterno max: 1,61 mm
  • Minimum cable diameter: 1,46 mm
  • Conductor stranding: 19 x 0.25
  • Peso Massimo: 10,43 g/m
  • Nominal weight: 10,15 g/m
  • Massima resistenza el. del cond. a 20°C in c.c.: 21,1 Ohm/km

 

EN 2267-010A 012

Rif. Nexans

  • Calibro (AWG): 18
  • Maximum core diameter: 1,45 mm
  • minimum core diameter: 1,41 mm
  • Diametro esterno max: 1,92 mm
  • Minimum cable diameter: 1,76 mm
  • Conductor stranding: 19 x 0.30
  • Peso Massimo: 14,61 g/m
  • Nominal weight: 14,05 g/m
  • Massima resistenza el. del cond. a 20°C in c.c.: 14,5 Ohm/km

 

EN 2267-010A 020

Rif. Nexans

  • Calibro (AWG): 14
  • Maximum core diameter: 1,73 mm
  • minimum core diameter: 1,69 mm
  • Diametro esterno max: 2,24 mm
  • Minimum cable diameter: 2,04 mm
  • Conductor stranding: 37 x 0.25
  • Peso Massimo: 19,78 g/m
  • Nominal weight: 19,31 g/m
  • Massima resistenza el. del cond. a 20°C in c.c.: 10,9 Ohm/km

 

EN 2267-010A 030

Rif. Nexans

  • Calibro (AWG): 12
  • Maximum core diameter: 2,18 mm
  • minimum core diameter: 2,13 mm
  • Diametro esterno max: 2,7 mm
  • Minimum cable diameter: 2,5 mm
  • Conductor stranding: 37 x 0.32
  • Peso Massimo: 31,33 g/m
  • Nominal weight: 29,25 g/m
  • Massima resistenza el. del cond. a 20°C in c.c.: 6,8 Ohm/km

 

EN 2267-010A 051

Rif. Nexans

  • Calibro (AWG): 10
  • Maximum core diameter: 2,77 mm
  • minimum core diameter: 2,73 mm
  • Diametro esterno max: 3,33 mm
  • Minimum cable diameter: 3,13 mm
  • Conductor stranding: 61 x 0.32
  • Peso Massimo: 49,85 g/m
  • Nominal weight: 47,37 g/m
  • Massima resistenza el. del cond. a 20°C in c.c.: 4,1 Ohm/km

 

EN 2267-010A 090

Rif. Nexans

  • Calibro (AWG): 8
  • Maximum core diameter: 3,85 mm
  • minimum core diameter: 3,55 mm
  • Diametro esterno max: 4,4 mm
  • Minimum cable diameter: 4,1 mm
  • Conductor stranding: 127 x 0.30
  • Peso Massimo: 90 g/m
  • Nominal weight: 87,81 g/m
  • Massima resistenza el. del cond. a 20°C in c.c.: 2,3 Ohm/km

 

EN 2267-010A 140

Rif. Nexans

  • Calibro (AWG): 6
  • Maximum core diameter: 5,2 mm
  • minimum core diameter: 4,8 mm
  • Diametro esterno max: 5,7 mm
  • Minimum cable diameter: 5,3 mm
  • Conductor stranding: 27 x 7 x 0.30
  • Peso Massimo: 135 g/m
  • Nominal weight: 132,41 g/m
  • Massima resistenza el. del cond. a 20°C in c.c.: 1,58 Ohm/km

 

EN 2267-010A 220

Rif. Nexans

  • Calibro (AWG): 4
  • Maximum core diameter: 6,8 mm
  • minimum core diameter: - mm
  • Diametro esterno max: 7,41 mm
  • Minimum cable diameter: 6,71 mm
  • Conductor stranding: 37 x 12 x 0.25
  • Peso Massimo: 222 g/m
  • Nominal weight: 215,15 g/m
  • Massima resistenza el. del cond. a 20°C in c.c.: 0,97 Ohm/km

 

EN 2267-010A 340

Rif. Nexans

  • Calibro (AWG): 2
  • Maximum core diameter: 8,6 mm
  • minimum core diameter: - mm
  • Diametro esterno max: 9,16 mm
  • Minimum cable diameter: 8,28 mm
  • Conductor stranding: 37 x 19 x 0.25
  • Peso Massimo: 347 g/m
  • Nominal weight: 336,1 g/m
  • Massima resistenza el. del cond. a 20°C in c.c.: 0,61 Ohm/km

 

Descrizione

Descrizione

Norme

  • Product
    EN 2267-010

Design Construction
 

1-Core
Stranded Conductor : Nickel Plated High

Strength Copper Alloy (AWG 26 & 24) or
Nickel Plated Copper (AWG 22 to 2)

 

2-Insulation
Special Polyimide Tape
Special UV PTFE Tape(s)

 

IDENTIFICATION 

Standard colour code :
White except AWG 26 which is light yellow and AWG 22 which is light green
AWG 24 is available in light blue color (EN2267-010A 002B)

Color of marking: green 
Marking text: EN DR ** FR F ++

 

DR = Short designation
** = AWG Wire Size
FR = Country of origin (FR = France)
F = Manufacturer (F = Nexans)
++ = Year of production (i.e. 13 = 2013)

 

Caratteristiche

Caratteristiche

Caratteristiche elettriche

Caratteristiche elettriche

Frequenza massima di funzionamento
0,002 MHz
Operating Voltage Vo DC
28 V
Operating voltage between phase and neutral
115 V
Operating voltage between phases
200 V

Caratteristiche d'utilizzo

Caratteristiche d'utilizzo

Temperatura Operativa
-55 ... 260 °C
Resistenza all'olio
Very good resistance to aircraft fluids
Arc tracking resistant
Yes

Risorse

Risorse

Contattaci

Argomenti su cui si desidera ottenere maggiori informazioni:

Campi obbligatori*

Si prega di controllare l'inserimento e riprovare.

Un indirizzo e-mail deve contenere una sola @

Protezione dei dati personali

Avete il diritto di opporvi al trattamento dei vostri dati personali e/o al loro utilizzo a fini di marketing diretto o commerciale

Grazie!

Grazie per averci contattato. Ci metteremo in contatto con te a breve.

Errore

Si è verificato un errore. Si prega di riprovare.

Chiudi

Contattaci

Campi obbligatori*

Si prega di controllare l'inserimento e riprovare.

Un indirizzo e-mail deve contenere una sola @

Protezione dei dati personali

Avete il diritto di opporvi al trattamento dei vostri dati personali e/o al loro utilizzo a fini di marketing diretto o commerciale

Grazie!

Grazie per averci contattato. Ci metteremo in contatto con te a breve.

Errore

Si è verificato un errore. Si prega di riprovare.

Chiudi