FLAMEX® FIRE RESISTANT WTB-MVB & CAN BUS 120 Ω
FLAMEX® FIRE RESISTANT WTB-MVB & CAN BUS 120 Ω
FLAMEX
FIRE RESISTANT DATA CABLES
Fostering innovation, Lynxeo designed FLAMEX® EN 50200 MVB, WTB and CAN BUS cables that can reach data transmission performances for Category 5E or 6A as described in the ISO/CEI 11801, showing no loss of data train and no drop of the transmission parameters when burnt. This unique fire performance is achievable thanks to our technology for fire resistant cables known as INFITTM. On top of the fire performances, this technology makes easier and faster the preparation and the connection of the wires with rolling stock connectors compared to older taping technologies.
FLAMEX CAN BUS 1x2x0.5² + 1x0.5²
Rif. Nexans 13117047 - Paese rif. 2PN347
- Imballo: Drum (1000m)
- Costruzione: 1x2x0,5 + 1x0,5
- Minimum cable diameter: 9,8 mm
- Maximum cable diameter: 10,2 mm
- Peso approssimativo del cavo: 125 kg/km
FLAMEX MVB 1x2x0.5²
Rif. Nexans 2PM599 - Paese rif. 2PM599
- Imballo: Drum (1000m)
- Costruzione: 1x2x0,5
- Minimum cable diameter: 9,5 mm
- Maximum cable diameter: 10 mm
- Peso approssimativo del cavo: 122 kg/km
FLAMEX MVB 4x0.5²
Rif. Nexans 10282384 - Paese rif. 2PM600
- Imballo: Drum (1000m)
- Costruzione: 4x0,5
- Minimum cable diameter: 10,8 mm
- Maximum cable diameter: 11,2 mm
- Peso approssimativo del cavo: 135 kg/km
FLAMEX WTB 1x2x0.75²
Rif. Nexans 10282314 - Paese rif. 2PM601
- Imballo: Drum (1000m)
- Costruzione: 1x2x0,75
- Minimum cable diameter: 11,3 mm
- Maximum cable diameter: 11,7 mm
- Peso approssimativo del cavo: 160 kg/km
Descrizione
Descrizione
Norme
-
ProductEN 50464-1; EN 45545-2 (HL3)
-
TestEN 50200
DESIGN
1. Conductor
Stranded tinned copper (metric or AWG sizes)
2. Insulation
Special halogen-free INFITTM fire proof material
Quad or Pairs assemblies
3. Screen
Tinned copper braid
Separator tape
4. Outer sheath
Cross-linked material EM 104 or EM 101 acc. EN 50264-1
Oil, diesel, ozone and UV resistant
Colour: red
Example of marking: FLAMEX 239 - ...
ADDITIONAL INFORMATION
- Fire resistant acc. to:
- EN 50200 PH 30-60 tested under 110 V
- EN 50200 PH 90 Ethernet frame loss and transmission parameter
- Bending radius:
- Static use: 8 x outer cable diameter
- For installation and occasional movements: 10 x outer cable diameter
Caratteristiche
Caratteristiche
Caratteristiche costruttive
Caratteristiche costruttive
Caratteristiche d'utilizzo
Caratteristiche d'utilizzo
Risorse
Risorse
I nostri siti web
Seleziona il tuo paese per trovare i nostri prodotti e soluzioni
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania