FLAMEX® 4GKW
FLAMEX® 4GKW
FLAMEX
UNSCREENED SINGLE CORE CABLE
FLAMEX® 4GKW power cables are used for fixed and protected installations. This product range is recommended for narrow spaces where an optimal bending radius is required. FLAMEX® cables are designed to withstand tough working conditions (oil, ozone, temperature variation, etc.). 120°C conductor temperature is allowed for a 20,000 hours cumulative working time.
FLAMEX 4GKW 1.8/3kV 1x1
Rif. Nexans 79461220
- Imballo: Cut to length (m)
- Sezione del conduttore del cavo: 1 mm²
- Diametro esterno min: 2,7 mm
- Diametro esterno max: 2,9 mm
- Peso approssimativo del cavo: 16 kg/km
FLAMEX 4GKW 1.8/3kV 1x1.5
Rif. Nexans 79461320
- Imballo: Cut to length (m)
- Sezione del conduttore del cavo: 1,5 mm²
- Diametro esterno min: 3,1 mm
- Diametro esterno max: 3,3 mm
- Peso approssimativo del cavo: 21 kg/km
FLAMEX 4GKW 1.8/3kV 1x2.5
Rif. Nexans 79461420
- Imballo: Cut to length (m)
- Sezione del conduttore del cavo: 2,5 mm²
- Diametro esterno min: 3,55 mm
- Diametro esterno max: 3,85 mm
- Peso approssimativo del cavo: 32 kg/km
FLAMEX 4GKW 1.8/3kV 1x4
Rif. Nexans 79461520
- Imballo: Cut to length (m)
- Sezione del conduttore del cavo: 4 mm²
- Diametro esterno min: 4,35 mm
- Diametro esterno max: 4,65 mm
- Peso approssimativo del cavo: 48 kg/km
FLAMEX 4GKW 1.8/3kV 1x6
Rif. Nexans 79461620
- Imballo: Cut to length (m)
- Sezione del conduttore del cavo: 6 mm²
- Diametro esterno min: 4,95 mm
- Diametro esterno max: 5,25 mm
- Peso approssimativo del cavo: 66 kg/km
FLAMEX 4GKW 1.8/3kV 1x10
Rif. Nexans 79461720
- Imballo: Cut to length (m)
- Sezione del conduttore del cavo: 10 mm²
- Diametro esterno min: 6,1 mm
- Diametro esterno max: 6,5 mm
- Peso approssimativo del cavo: 110 kg/km
FLAMEX 4GKW 1.8/3kV 1x16
Rif. Nexans 79461820
- Imballo: Cut to length (m)
- Sezione del conduttore del cavo: 16 mm²
- Diametro esterno min: 8,1 mm
- Diametro esterno max: 8,5 mm
- Peso approssimativo del cavo: 190 kg/km
Descrizione
Descrizione
Norme
-
ProductEN 45545-2 (HL3); EN 50264-3-1; IEC 60228
DESIGN
1. Conductor
Flexible stranded tinned copper, class 5 acc. to IEC 60228
Optional halogen-free separator tape
2. Insulation
Cross-linked compound type EI 109 acc. to EN 50264-1
Oil, diesel, ozone and UV resistant
Colour: black
Example of cable marking up to 10 mm²: FLAMEX type EN 50264-3-1 1800V (mm²) M 4GKW I LYNXEO I WW-YYYY
Example of cable marking from 16 mm²: FLAMEX EN 50264-3-1 1800V (mm²) M I LYNXEO I WW-YYYY
GUIDE TO USE
- Cabling rules are given in EN 50343 and EN 50355
- Permissible current carrying capacities: values and calculation method are given in EN 50343
- Bending radius:
- Static use: 3 x outer cable diameter (5 x D if D > 10mm)
- For installation and occasional movements: 6 x outer cable diameter
Caratteristiche
Caratteristiche
Caratteristiche costruttive
Caratteristiche costruttive
Caratteristiche elettriche
Caratteristiche elettriche
Caratteristiche d'utilizzo
Caratteristiche d'utilizzo
I nostri siti web
Seleziona il tuo paese per trovare i nostri prodotti e soluzioni
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania