ENERGYFLEX BE-FAST

Productos

ENERGYFLEX 2x1x10² 1.5kV DC

Lynxeo ref.

  • Embalaje: Bobina
  • Sección del conductor: 10 mm²
  • Nominal conductor diameter: 4 mm
  • Diámetro exterior nominal: 7,3 mm
  • Approximate diameter of the bunched cable: 15,0 mm
  • Peso aproximado: 260 kg/km
  • Resistencia máxima del conductor en CC a 20º C: 1,95 Ohm/km
  • Permissible current rating in air 60°C: 70 A
  • Permissible current rating on a tray 60°C: 68 A
  • Permissible short circuit current conductor 1s: 1,4 kA

 

ENERGYFLEX 2x1x4² 1.5kV DC

Lynxeo ref.

  • Embalaje: Bobina
  • Sección del conductor: 4 mm²
  • Nominal conductor diameter: 2,5 mm
  • Diámetro exterior nominal: 5,7 mm
  • Approximate diameter of the bunched cable: 11,8 mm
  • Peso aproximado: 128 kg/km
  • Resistencia máxima del conductor en CC a 20º C: 5,09 Ohm/km
  • Permissible current rating in air 60°C: 40 A
  • Permissible current rating on a tray 60°C: 38 A
  • Permissible short circuit current conductor 1s: 0,5 kA

 

ENERGYFLEX 2x1x6² 1.5kV DC Nuevo

Lynxeo ref.

  • Embalaje: Bobina
  • Sección del conductor: 6 mm²
  • Nominal conductor diameter: 2,9 mm
  • Diámetro exterior nominal: 6,2 mm
  • Approximate diameter of the bunched cable: 12,8 mm
  • Peso aproximado: 165 kg/km
  • Resistencia máxima del conductor en CC a 20º C: 3,39 Ohm/km
  • Permissible current rating in air 60°C: 51 A
  • Permissible current rating on a tray 60°C: 49 A
  • Permissible short circuit current conductor 1s: 0,8 kA

 

Descripción

Descripción

Estándares

  • Producto
    EN 50618; IEC 60228; IEC 62930

DESIGN

Double cores solar cable with low smoke, halogen free, crosslinked insulation and sheath.

1. Conductor
   Stranded tinned copper wires class 5 acc. IEC 60228

2. Insulation
   Cross-linked halogen-free rubber
   Colour: white

3. Sheath
   Cross-linked halogen-free fire retardant rubber
   Colour: black

 

Example of marking: ENERGYFLEX® USE < HAR > H1Z2Z2-K 62930 IEC 131 1 x S mm² 1.5/1.5 (1,8) kV DC NEXANS 269 MADE IN FRANCE Dca


FEATURES

ENERGYFLEX® cables are dedicated to the photovoltaic system direct current (D.C.) side with a nominal D.C. voltage of 1.5 kV and a maximum D.C. voltage of 1.8 kV. Cable suitable to be used with Class II equipment. 

These cables are suitable for permanent outdoor long-term use, under variable and harsh climate conditions. They are designed and tested to operate at a normal maximum conductor temperature of 90°C and for 20,000 hours up to 120°C. Therefore, the expected period use is 30 to 40 years under normal usage conditions (lifetime acc. to Arrhenius Diagram).

ENERGYFLEX® cables have a suitable behaviour in water : tests of Annexes D and E of H07RN8F AD8 cables (100 days at 50 °C under 1 kV AC without breakdown), and additional test of 1,5 year in hot water (85°C) under 1 kV DC without breakdown. They are suitable for submerged installations with a maximum cumulated immersion period of 4 months / year.

LIST OF CERTIFICATES

NF EN 50618: BUREAU VERITAS LCIE licence 662568
IEC 62930: BUREAU VERITAS Certificate of conformity 158416-729944
Construction Product Regulation (CPR) Performance: Dca-s2,d2,a1

Características

Características

Características de construcción

Características de construcción

Libre de halógenos
IEC 60754-1

Características dimensionales

Características dimensionales

Number of cables
2
Nominal insulation thickness
0,7 mm
Nominal outer sheath thickness
0,8 mm

Características eléctricas

Características eléctricas

Tensión nominal de servicio Uo/U
1.0/1.0 (1.2) kV AC 1.5/1.5 (1.8) kV DC

Características de uso

Características de uso

No propagador del incendio
EN 50575
No propagación de la llama
IEC 60332-1-2
Densidad de los humos
IEC 61034-2
Corrosividad de los gases
Baja IEC 60754-2
Resistencia a la intemperie
Excelente
Resistancia al ozono
EN 50396
Thermal endurance
IEC 60216-1-2
Temperatura ambiente de utilización (rango)
-40 ... 90 °C
Temperatura máxima operativa
120 °C

Recursos

Recursos

Contáctanos

Temas sobre los que desea recibir mayor información

Campos requeridos

Por favor revise la data ingresada e intente nuevamente

El correo debe contener este símbolo @

Protección de data personal

Tiene el derecho de rechazar el procesamiento de sus datos personales y/o su uso para propósitos comerciales

¡Gracias!

Gracias por contactarse con nosotros. Nos pondremos en contacto pronto.

Error

Ocurrió un error. Por favor intentar nuevamente

Cerrar

Contáctanos

Campos requeridos

Por favor revise la data ingresada e intente nuevamente