EN 2713-012 Type MNA, MNB, MNC, MND
EN 2713-012 Type MNA, MNB, MNC, MND
Designed for general Purpose Aircraft Wiring Applications.
Multicore cables shielded an jacketed
200 °C, Light Weight , UV
Arc Tracking Resistant
Descripción
Descripción
Estándares
-
ProductoEN 2267-009
-
EnsayoprEN 3475
DESIGN CONSTRUCTION
CORES
1, 2, 3 or 4 cores
EN 2267-009A
SCREEN
Silver plated copper spiral screen
JACKET
Polyimide tape
UV Laser markable
Top coat
ELECTRICAL AND HIGH FREQUENCY PERFORMANCES
Voltage rating : 600 Volts RMS at sea level,
Usual Aerospace application are using 115 volts (Phase to neutral)
And 200 Volts (Phase to phase) 400 Hz AC or 29 Volts DC.
Maximum operating frequency: 2000Hz
Identification
| CORES | |
| Colour of cores | : See table on this datasheet |
| Colour of marking | : White for Red and Green core, |
| Green for Blue, White and Yellow core | |
| Marking | : EN DR A ++ FRF** |
| JACKET | |
| Colour of Jacket | : See table on this datasheet |
| Colour of marking | : Green |
| Marking | : MNx ++ FRF** |
| MNx = Short designation (MNA, MNB, MNC, MND) | |
| ++ = AWG | |
| FR = Country of Origin (FR = France) | |
| F = Manufacturer (F = Nexans) | |
| ** = Year of manufacturing (ie. 10 = 2010) |
Características
Características
Características eléctricas
Características eléctricas
Maximal operating frequency
0,002 MHz
Operating Voltage Vo DC
28 V
Operating voltage between phases
200 V
Operating voltage between phase and neutral
115 V
Características de uso
Características de uso
Temperatura ambiente de utilización (rango)
-55 ... 200 °C
Resistencia a aceites
Very good resistance to aircraft fluids
No propagación de la llama
FAR/JAR part 25 sec 25.869 (a)(4) Appendix F part 1 (3)
Arc tracking resistant
Yes