- Industrial Cables
- Your Business
- Company
- Newsroom
- Tools & Resources
- Career
- Buscar
- Contáctanos
- Comparar
- Registrarse
DRB 26 001
DRB 26 001
Designed for general Purpose Aircraft Wiring Applications.
Multicores DRA
- Lynxeo ref. : EN 2267-009B 001P (DRB 26)
- País de referencia : 10066375
Descripción
Descripción
Estándares
-
ProductoEN 2267-009
-
EnsayoprEN 3475
DESIGN CONSTRUCTION
CORES
2, 3 or 4 cores EN2267-009A
IDENTIFICATION
| Colours of cores | : See table in this datasheet |
|
Colours of marking |
: White for red and green core, green for blue and yellow cores |
| Marking | : EN DRA ** FR F ++ |
| DRA = short designation | |
| ** = AWG | |
| FR = Country of origin (FR = France) | |
| F = Manufacturer (F = Lynxeo) | |
| ++ = Year of production (i.e. 14 = 2014) |
ELECTRICAL AND HIGH FREQUENCY PERFORMANCES
Voltage rating : 600 Volts RMS at sea level,
Usual Aerospace application are using 115 volts (Phase to neutral)
And 200 Volts (Phase to phase) 400 Hz AC or 29 Volts DC.
Maximum operating frequency: 2000Hz
Características
Características
Características de construcción
Características de construcción
Color
P
Type of conductor
-
Core identification
Red, Blue
Number of conductors
-
Size code
-
Características dimensionales
Características dimensionales
Diámetro exterior máximo
1,68 mm
Diámetro exterior nominal
1,56 mm
Número de conductores
2
Maximum weight
4,28 g/m
Nominal weight
3,98 g/m
Características eléctricas
Características eléctricas
Maximal operating frequency
0,002 MHz
Maximum DC resistance at 20°C
165 Ohm/100m
Tensión de operación
600 V
Características de uso
Características de uso
No propagación de la llama
FAR/JAR part 25 sec 25.869 (a)(4) Appendix F part 1 (3)
Resistencia a aceites
Very good resistance to aircraft fluids
Arc tracking resistant
Yes
Acorde con normativa RoHs
Si
Temperatura ambiente de utilización (rango)
-55 ... 260 °C