DRC 8 090
DRC 8 090
Designed for general Purpose Aircraft Wiring Applications.
Multicores DRA
- Lynxeo ref. : EN 2267-009C 090P (DRC 8)
- País de referencia : 10068342
Descripción
Descripción
Estándares
-
ProductoEN 2267-009
-
EnsayoprEN 3475
DESIGN CONSTRUCTION
CORES
2, 3 or 4 cores EN2267-009A
IDENTIFICATION
| Colours of cores | : See table in this datasheet |
|
Colours of marking |
: White for red and green core, green for blue and yellow cores |
| Marking | : EN DRA ** FR F ++ |
| DRA = short designation | |
| ** = AWG | |
| FR = Country of origin (FR = France) | |
| F = Manufacturer (F = Lynxeo) | |
| ++ = Year of production (i.e. 14 = 2014) |
Identification
| Colours of cores | : See table in this datasheet |
|
Colours of marking |
: White for red and green core, green for blue and yellow cores |
| Marking | : EN DRA ** FR F ++ |
| DRA = short designation | |
| ** = AWG | |
| FR = Country of origin (FR = France) | |
| F = Manufacturer (F = Lynxeo) | |
| ++ = Year of production (i.e. 14 = 2014) |
Características
Características
Características de construcción
Características de construcción
Color
P
Type of conductor
-
Core identification
Red,Blue,Yellow
Number of conductors
-
Size code
-
Características dimensionales
Características dimensionales
Diámetro exterior máximo
9,46 mm
Diámetro exterior nominal
9,27 mm
Número de conductores
3
Maximum weight
278,1 g/m
Nominal weight
268,7 g/m
Características eléctricas
Características eléctricas
Maximal operating frequency
0,002 MHz
Maximum DC resistance at 20°C
2,37 Ohm/100m
Tensión de operación
600 V
Características de uso
Características de uso
No propagación de la llama
FAR/JAR part 25 sec 25.869 (a)(4) Appendix F part 1 (3)
Resistencia a aceites
Very good resistance to aircraft fluids
Arc tracking resistant
Yes
Acorde con normativa RoHs
Si
Temperatura ambiente de utilización (rango)
-55 ... 260 °C