WINDLINK® LV-RS (N)HXMFOE 0.6/1 kV
WINDLINK® LV-RS (N)HXMFOE 0.6/1 kV
Torsion resistant low-voltage loop cable for free hanging of max. 100 m
Design acc. to EN 50525-2-21
Descrizione
Descrizione
Norme
-
ProductEN 50264; EN 50363; IEC 60502
Application
Low-voltage trailing cable RHEYWIND LV-RS (N)HXMFOE in two sheath design was developed for special application condition in windmills. The construction is torsion resistance by free hanging max. 100 m. These cables are specified for medium mechanical stress and for operation under permanent influence of seawater and usage outdoor.
Resistance against:
- permanent movement
- permanent vibrations
- compressive stress
- oil
- leach
- flame-retardant
- temporary influence of seawater
- weather
- UV
- Ozone influence, suitable for moving outdoor
- suitable for torsion of max. 6 counterclockwise rotations and min. free hanging up from 25 m
Design
Conductor
Copper, plain, flexible stranded, class 5 acc. to DIN EN 60228
Insulation
Elastomeric special compound
Outer Sheath
Elastomeric special compound:
- HM3 acc. EN 50361, based on: EVA
- water and oil resistant, flame retardant, abrasion and notch-resistant
- colour: black
Operating condition
Temperatures | moved transport and stock operating temperature at conductor short circuit teperature at conductor |
-40/+ 90 °C -40/+90 °C 90 °C 250°C |
Max. tensile load | short time, e.g.speed up N/mm² in operation |
50 15 |
Bending radii | fixed free moving Inlet ant strain relief |
³ 3 x D ³ 5 x D ³ 5 x D (D = cable diameter) |
Torsion | max. permissible angle | ± 150 °/m |
Caratteristiche
Caratteristiche
Caratteristiche costruttive
Caratteristiche costruttive
Caratteristiche dimensionali
Caratteristiche dimensionali
Caratteristiche elettriche
Caratteristiche elettriche
Caratteristiche d'utilizzo
Caratteristiche d'utilizzo
Risorse
Risorse
Vendita e consegna Informazioni
Inkjet Markierung WINDLINK® LV-RS (N)HXMFOE 1x95 0.6/1 kV I NEXANS I