(N)HXCSLOE-JZ 25x1
Description
Description
Standards
-
ProductEN 50363; HD 22-13; IEC 60228; IEC 60502
Applications
Low voltage loop cable WINDLINK LV-RS (N)HXSLOE was developed for special application conditions in wind turbines. The construction is torsion resistant by free hanging of max. 100 m. These cables are specified for medium mechanical stress and for operation under permanent influence of sea water and usage outdoor.
Resistance to
- permanent movement
- permanent vibrations
- compressive stress
- oil, EN60811-2-1, ASTM No.2, 24h at 100°C
- low smoke, IEC 61034, >50 %
- halogen-free IEC 60754
- permanent influence of sea water
- ozone influence, EN 60811-2-1 clause 8
- suitable for torsion of max. 6 counterclockwise rotations and min. free hanging up from 25 m
Design
Core
Conductor
- Copper, plain, flexible concentrically stranded circular
Insulation
- Extruded halogen-free rubber compound EI8 acc. to EN 50363-5
Outer Sheath
- Extruded halogen-free EVA compound EM8 acc. to EN 50363-6
Characteristics
Characteristics
구조적 특성
구조적 특성
도체 재료
Plain annealed copper
Conductor flexibility
소프트 레벨 5
절연
고무
피복
고무 복합체
Sheath colour
검은색
Halogen free
IEC 60754-2
Overall screen
-
With Green/Yellow core
예
치수
치수
코어수
25
도체 단면적
1 mm²
Copper content
0 kg/km
Nominal outer diameter
20.0 mm
무게(근사치)
550 kg/km
전기적 특성
전기적 특성
정격전압 Uo/U (Um)
0,6/1 kV
사용 특성
사용 특성
난연
EN 50265-2-1
Silicone free
Yes
RoHS compliant
Yes
Max. conductor temperature in service
90 °C
Weather resistance
Excellent
Short-circuit max. conductor temperature
250 °C
Resources
Resources
Documentation
UL certificate
pdf — 676.6 kB
Selling & delivery Information
Inkjet marking e.g.: WINDLINK LV-RS (N)HXSLOE 0.6/1 kV I NEXANS I
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania