FLAMEX® FR TYPE EN 50306-2
FLAMEX® FR TYPE EN 50306-2
FLAMEX
FIRE RESISTANT CONTROL WIRES
FLAMEX® Fire Resistant control wires TYPE EN 50306-2 maintain circuit integrity in case of fire (according to EN 50200 for 120 minutes) and are fire retardant, low smoke and halogenfree safisfying performance requirements of EN 45545-2 HL3. In addition, FLAMEX® cables withstand the tough working conditions of rolling stock (oil, ozone, temperature variations, etc.).
FLAMEX 20 TYPE MSZ 1X0.5
Product ref. 13101504 - Country ref. 2PN299
- 도체 단면적: 0.5 mm²
- Conductor diameter (mm): 0.95
- Minimum cable diameter: 1.7 mm
- Maximum cable diameter: 2 mm
- 무게(근사치): 7.5 kg/km
FLAMEX 20 TYPE MSZ 1X0.75
Product ref. 13112324 - Country ref. 2PN300
- 도체 단면적: 0.75 mm²
- Conductor diameter (mm): 1.15
- Minimum cable diameter: 1.9 mm
- Maximum cable diameter: 2.2 mm
- 무게(근사치): 10 kg/km
FLAMEX 20 TYPE MSZ 1X1.0
Product ref. 13112325 - Country ref. 2PN301
- 도체 단면적: 1 mm²
- Conductor diameter (mm): 1.30
- Minimum cable diameter: 2 mm
- Maximum cable diameter: 2.3 mm
- 무게(근사치): 12.1 kg/km
FLAMEX 20 TYPE MSZ 1X1.5
Product ref. 13112327 - Country ref. 2PN302
- 도체 단면적: 1.5 mm²
- Conductor diameter (mm): 1.60
- Minimum cable diameter: 2.5 mm
- Maximum cable diameter: 2.9 mm
- 무게(근사치): 18.2 kg/km
FLAMEX 20 TYPE MSZ 1X2.5
Product ref. 13101505 - Country ref. 2PN303
- 도체 단면적: 2.5 mm²
- Conductor diameter (mm): 2.00
- Minimum cable diameter: 2.9 mm
- Maximum cable diameter: 3.3 mm
- 무게(근사치): 27.6 kg/km
Description
Description
Standards
-
ProductEN 45545-2 (HL3)
-
TestEN 50200; EN 50305; EN 50306; IEC 60331-2
DESIGN
1. Conductor
Flexible stranded tinned copper
2. Insulation
Mineral tape as fire barrier
Thin wall halogen-free cross-linked material acc. EN 50306-2
Colour: white
Example of marking: FLAMEX 239 - EDE 2PN299 - TYPE EN 50306-2 - EN 50200 - 300 V - 1x0.5 - M - week/year - batch number
GUIDE TO USE
- Cabling rules are given in EN 50343 and EN 50355
- Permissible current carrying capacities: values and calculation method are given in EN 50343
- Bending radius:
- Static use: 5 x outer cable diameter
- For installation and occasional movements: 10 x outer cable diameter