FLAMEX TYPE EN 50264-3-1 FR 1800V 1x1.5²

Description

Description

Standards

  • Product
    EN 50264-3-1; EN 45545 - HL3; IEC 60228
  • Test
    EN 50200; IEC 60331-1 or 2

FLAMEX® EN50264-3-1 FR flexible power cables maintain circuit integrity in case of fire (according to EN 50200 for 90 minutes) and are fire retardant, low smoke and halogen-free safisfying performance requirements of EN 45545-2-HL3. On top of that, FLAMEX® cables withstand tough working conditions (oil, ozone, temperature variations, etc.).

 

DESIGN

1.  Conductor 
Flexible stranded tinned copper, class 5  acc. to IEC 60228
Mineral tape

2.  Insulation
Cross-linked compound type EI 109  acc. to EN 50264-1
Oil, diesel, ozone and UV resistant
Colour: black

Examples of marking: 
FLAMEX HXAFOE FR 1,8/3 kV EN 50264-3-1 1800 V (mm²) OM  I LYNXEO I WW-YYYY or FLAMEX 4GKW-EN FR 1,8/3 kV EN 50264-3-1  1800 V (mm²) OM  I LYNXEO I WW-YYYY

FIRE SAFETY

FLAMEX® FR TYPE EN 50264-3-1 power cables are conform to EN 45545-2 HL3. Fire resistant according to EN 50200 / IEC 60331-1 or -2

GUIDE TO USE

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 3 x outer cable diameter if D ≤ 10mm / 5 x outer cable diameter if D > 10mm
    • For installation and occasional movements: 10 x outer cable diameter

 

 

   
 

 

Characteristics

Characteristics

구조적 특성

구조적 특성

도체 재료
Tin plated copper
Conductor flexibility
소프트 레벨 5
Halogen free
EN 60754-1 & EN 60684-2
절연
Cross-linked compound
Insulation colour
Black

치수

치수

도체 단면적
1.5 mm²
Minimum outer diameter
3.7 mm
Maximum outer diameter
3.9 mm
무게(근사치)
21 kg/km
코어수
1

전기적 특성

전기적 특성

정격전압 Uo/U (Um)
1.8 / 3 (3.6) kV
Maximum operating voltage
2.7 kV

사용 특성

사용 특성

Fire resistant
IEC 60331­-1 or -2
난연
EN 60332-1-2
Fire retardant
EN IEC 60332-3-24 (cat C); EN IEC 60332-3-25 (EN50305)
연기밀도
EN/IEC 61034-2
유독가스
EN 50305-9.2
操作温度范围
-40 ... 90 °C
Max. conductor temperature in service
90 °C
Overload maximum core temperature
120 °C
Chemical resistance
Good
Ozone resistance
Yes
U.V resistance
Yes
Fire load
0.04 kWh/m

Resources

Resources

Documentation

xls — 0 B
xls — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close