FLAMEX EN 50264-3-1 3600V 10 MMS

Description

Description

Standards

  • Product
    EN 50264-3-1; EN 45545 - HL3; IEC 60228

DESIGN

1. Conductor 
     Flexible stranded tinned copper, class 5 acc. to IEC 60228
     Optional halogen-free separator tape

2. Insulation 
    Cross-linked compound type El 109 acc. to EN 50264-1
    Colour: black or grey

3. Screen
     Halogen-free foil,  tinned copper wire braid, halogen-free separator

4. Outer sheath 
    Cross-linked compound  type EM 104 acc. to EN 50264-1
    Oil, diesel, ozone and UV resistant
    Colour: black

 

Example of marking: FLAMEX EN 50264-3-1 3600V (mm²) MM  (N)SHXAFCOE 3.6/6 kV I LYNXEO I WW-YYYY

GUIDE TO USE

 

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 5 x outer cable diameter (6 x D if D > 10mm)
    • For installation and occasional movements: 10 x outer cable diameter

Characteristics

Characteristics

구조적 특성

구조적 특성

도체 재료
Tin plated copper
Conductor flexibility
소프트 레벨 5
절연
Cross-linked compound
스크린
주석 도금 구리 브레이드
피복
Cross-linked compound
Halogen free
EN 60754-1 & EN 60684-2

치수

치수

도체 단면적
10 mm²
Minimum outer diameter
12.5 mm
Maximum outer diameter
13.1 mm
무게(근사치)
280 kg/km
Braid section
6 mm²
코어수
1

전기적 특성

전기적 특성

정격전압 Uo/U (Um)
3.6 / 6 (7.2) kV

사용 특성

사용 특성

난연
IEC 60332-1-2
Fire retardant
EN IEC 60332-3-24 (cat C); EN IEC 60332-3-25 (EN50305)
연기밀도
EN/IEC 61034-2
유독가스
EN 50305-9.2
Electro magnetic interference resistance
Yes
操作温度范围
-40 ... 90 °C
Max. conductor temperature in service
90 °C
Overload maximum core temperature
120 °C
Chemical resistance
Excellent
Ozone resistance
Yes
U.V resistance
Yes
Fire load
0.75 kWh/m
Short-circuit max. conductor temperature
200 °C

Resources

Resources

Documentation

xls — 0 B
xls — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close