FLAMEX EN 50382-2 3600V 120 FXZ 120°C

Description

Description

Standards

  • Product
    EN 45545-2 (HL3); EN 50382-2; IEC 60228

FLAMEX® EN 50382-2 3600V FXZ power cables are designed with extra flexible conductors and reinforced with textile braid to be used as a jumper cable between vehicles. Able to withstand higher operating temperatures, these silicone-based cables allow to save cable weight.

DESIGN

1. Conductor
Extra Flexible class 6 copper according to IEC 60228
    - tinned copper for 120°C Class
    - plain copper for 150°C Class
Separator: Unweaved tape 

2. Insulation
Cross-linked silicone type EI 111, according to EN 50382-1 with an embedded polyester reinforcement
Colour: black outer layer

Examples of marking:
FLAMEX SI - EN 50382-2  - 3600 V - cross-section mm² - FXZ - class temperature (120°C) - NEXANS 279 - week/year  
FLAMEX SI - DTREN 150028 - EN 50382-2  - 3600 V - cross-section mm² - FXZ - class temperature (120°C) - NEXANS 279 - week/year

 

FIRE SAFETY

FLAMEX® EN 50382-2 3600V FXZ power cables are conform to EN 45545-2 HL3

 

GUIDE TO USE

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 4 x outer cable diameter
    • For installation and occasional movements: 6 x outer cable diameter
  • Pulling tensible force (dynamic) during installation: 50 N/mm² of copper size
  • Mechanical static tensible force: 15N/mm² of copper size

 

Characteristics

Characteristics

구조적 특성

구조적 특성

도체 재료
Tin plated copper
Conductor flexibility
울트라 소프트 레벨 6
절연
High temperature silicone
Halogen free
EN 60754-1 & EN 60684-2

치수

치수

도체 단면적
120 mm²
도체지름
14.2 mm
Nominal outer diameter
20.8 mm
Minimum outer diameter
20.5 mm
Maximum outer diameter
24.3 mm
무게(근사치)
1480 kg/km

전기적 특성

전기적 특성

정격전압 Uo/U (Um)
3.6 / 6 (7.2) kV

사용 특성

사용 특성

난연
EN 60332-1-2
Fire retardant
EN IEC 60332-3-24 (cat C); EN IEC 60332-3-25 (EN50305)
연기밀도
EN/IEC 61034-2
유독가스
EN 50305-9.2
操作温度范围
-50 ... 120 °C
Max. conductor temperature in service
120 °C
Overload maximum core temperature
140 °C
Chemical resistance
Good

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close