HYBRID CABLES ACC. TO HEIDENHAIN HMC6® STANDARD
HYBRID CABLES ACC. TO HEIDENHAIN HMC6® STANDARD
Hybrid cables for servo motors for extremely dynamic applications MOTIONLINE® PREMIUM
Read moreHYBRID CABLES ACC. TO HEIDENHAIN HMC6® STANDARD (4G1,5+(2x1,0)C+(2x0,24+2x2x0,09)C)C
Nexans ref. 49391760
- Packaging: Drum (1000m)
- Construction type: (4G1,5+(2x1,0)C+(2x0,24+2x2x0,09)C)C
- Outer Diameter: 12.4 mm
- Copper content: 127 kg/km
- Approximate weight: 229 kg/km
HYBRID CABLES ACC. TO HEIDENHAIN HMC6® STANDARD (4G4,0+(2x1,0)C+(2x0,24+2x2x0,09)C)C
Nexans ref. 49391860
- Packaging: Drum (1000m)
- Construction type: (4G4,0+(2x1,0)C+(2x0,24+2x2x0,09)C)C
- Outer Diameter: 15.1 mm
- Copper content: 245 kg/km
- Approximate weight: 365 kg/km
Description
Description
Standards
-
ProductUL and CSA approval
Hybrid cables for servo motors for extremely dynamic applications; PUR Jacket; screened, resistant to oils and coolants, notch resistant, flame retardant, resistant to hydrolysis and microbes, PVC- and halogen-free.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Bending-resistant conductor with bare copper wires
Insulation
TPM with very low capacitance
Insulation colour
Power: Blu-Br-Blk-Gn/Ye; Brake: Wht-Wht/Blk; Supply: Br/Gn - Wht/Gn; Communication: Gry - Pnk - Vio - Ye
Lay Up
power cores and control pairs stranded with filler
Individual screen
Signal shield: Tinned copper braid, coverage >=80%
Screen
Tinned copper braid, coverage ≥ 80%
Inner sheath
TPE compound, optimized for drag chain use
Outer sheath
PUR
Sheath colour
Orange RAL 2003
Halogen free
Yes
Electrical characteristics
Electrical characteristics
Rated Voltage Uo/U
0.6/1 kV
Test voltage
4000 V
Mechanical characteristics
Mechanical characteristics
Bending cycles
5 Mio.
Maximum acceleration
50 m/s²
Speed
300 m/min
Usage characteristics
Usage characteristics
Field of application
Dynamic
Minimum dynamic operating bending radius
7.5 (xD)
Operating temperature, range
-30 ... 80 °C
Storage temperature, range
-50 ... 80 °C
Oil resistance
DIN EN 50363-10-2 & DIN EN 60811-404
Flame retardant
IEC 60332-1-2; UL 1581 FT1
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania