WINDLINK® Control LiHCH LSOH shielded
WINDLINK® Control LiHCH LSOH shielded
Halogenfree, shielded control cables LiHCH
LiHCH 10x1,0
Nexans ref.
- Packaging: m (1000m)
- Construction type: 10 x 1.0
- Insulation colour: Black numbered
- Number of cores: 10
- Conductor cross-section: 1 mm²
- Diameter over braid: 8.8 mm
- Nominal diameter: 10.7 inches
- Copper content: 78 kg/km
- Max. DC resistance of the conductor at 20°C: 19.5 Ohm/km
- Minimum bending radius, occasionally moving: 20 (xD)
- Minimum bending radius, fixed installation: 10 (xD)
LiHCH 12G1,0
Nexans ref.
- Packaging: m (1000m)
- Construction type: 12 G 1.0
- Insulation colour: Black numbered Yellow/Green
- Number of cores: 12
- Conductor cross-section: 1 mm²
- Diameter over braid: 9.1 mm
- Nominal diameter: 11.1 inches
- Copper content: 98 kg/km
- Max. DC resistance of the conductor at 20°C: 19.5 Ohm/km
- Minimum bending radius, occasionally moving: 20 (xD)
- Minimum bending radius, fixed installation: 10 (xD)
LiHCH 12x1,5
Nexans ref.
- Packaging: m (1000m)
- Construction type: 12 x 1.5
- Insulation colour: Black numbered
- Number of cores: 12
- Conductor cross-section: 1.5 mm²
- Diameter over braid: 10.4 mm
- Nominal diameter: 13 inches
- Copper content: 294 kg/km
- Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
- Minimum bending radius, occasionally moving: 8 (xD)
- Minimum bending radius, fixed installation: 4 (xD)
LiHCH 16x0,34
Nexans ref.
- Packaging: m (1000m)
- Construction type: 16x0,34
- Insulation colour: DIN 47100
- Number of cores: 16
- Conductor cross-section: 0.34 mm²
- Diameter over braid: 7.4 mm
- Nominal diameter: 9.3 inches
- Copper content: 58 kg/km
- Max. DC resistance of the conductor at 20°C: 57 Ohm/km
- Minimum bending radius, occasionally moving: 10 (xD)
- Minimum bending radius, fixed installation: 10 (xD)
LiHCH 2x0,75
Nexans ref.
- Packaging: m (1000m)
- Construction type: 2 x 0.75
- Insulation colour: DIN 47100
- Number of cores: 2
- Conductor cross-section: 0.75 mm²
- Diameter over braid: 4.4 mm
- Nominal diameter: 6 inches
- Copper content: 40 kg/km
- Max. DC resistance of the conductor at 20°C: 26 Ohm/km
- Minimum bending radius, occasionally moving: 20 (xD)
- Minimum bending radius, fixed installation: 10 (xD)
LiHCH 2x0,50
Nexans ref.
- Packaging: m (1000m)
- Construction type: 2x0,50
- Insulation colour: DIN 47100
- Number of cores: 2
- Conductor cross-section: 0.5 mm²
- Diameter over braid: 4.0 mm
- Nominal diameter: 5.6 inches
- Copper content: 107 kg/km
- Max. DC resistance of the conductor at 20°C: 39 Ohm/km
- Minimum bending radius, occasionally moving: 10 (xD)
- Minimum bending radius, fixed installation: 10 (xD)
LiHCH 2x1,5
Nexans ref.
- Packaging: m (1000m)
- Construction type: 2x1,5
- Insulation colour: Black numbered
- Number of cores: 2
- Conductor cross-section: 1.5 mm²
- Diameter over braid: 5.3 mm
- Nominal diameter: 7.1 inches
- Copper content: 98 kg/km
- Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
- Minimum bending radius, occasionally moving: 20 (xD)
- Minimum bending radius, fixed installation: 10 (xD)
LiHCH 3x2x0,34
Nexans ref.
- Packaging: m (1000m)
- Construction type: 3 x 2 x 0.34
- Insulation colour: DIN 47100
- Number of cores: 6
- Conductor cross-section: 0.34 mm²
- Diameter over braid: 5.8 mm
- Nominal diameter: 7.6 inches
- Copper content: 70 kg/km
- Max. DC resistance of the conductor at 20°C: 57 Ohm/km
- Minimum bending radius, occasionally moving: 10 (xD)
- Minimum bending radius, fixed installation: 10 (xD)
LiHCH 3x2x0,50
Nexans ref.
- Packaging: m (1000m)
- Construction type: 3 x 2 x 0.50
- Insulation colour: DIN 47100
- Number of cores: 6
- Conductor cross-section: 0.5 mm²
- Diameter over braid: 6.6 mm
- Nominal diameter: 8.4 inches
- Copper content: 137 kg/km
- Max. DC resistance of the conductor at 20°C: 39 Ohm/km
- Minimum bending radius, occasionally moving: 10 (xD)
- Minimum bending radius, fixed installation: 10 (xD)
LiHCH 3G0,75
Nexans ref.
- Packaging: m (1000m)
- Construction type: 3G0,75
- Insulation colour: Brown - Light blue - Green/yellow.
- Number of cores: 3
- Conductor cross-section: 0.75 mm²
- Diameter over braid: 4.6 mm
- Nominal diameter: 6.3 inches
- Copper content: 50 kg/km
- Max. DC resistance of the conductor at 20°C: 26 Ohm/km
- Minimum bending radius, occasionally moving: 8 (xD)
- Minimum bending radius, fixed installation: 8 (xD)
LiHCH 3G1,5
Nexans ref.
- Packaging: m (1000m)
- Construction type: 3G1,5
- Insulation colour: Black numbered Yellow/Green
- Number of cores: 3
- Conductor cross-section: 1.5 mm²
- Diameter over braid: 5.6 mm
- Nominal diameter: 7.4 inches
- Copper content: 158 kg/km
- Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
- Minimum bending radius, occasionally moving: 20 (xD)
- Minimum bending radius, fixed installation: 10 (xD)
LiHCH 3G6
Nexans ref.
- Packaging: m (1000m)
- Construction type: 3G6
- Insulation colour: Black numbered Yellow/Green
- Number of cores: 3
- Conductor cross-section: 6 mm²
- Diameter over braid: 9.7 mm
- Nominal diameter: 12.1 inches
- Copper content: - kg/km
- Max. DC resistance of the conductor at 20°C: 3.3 Ohm/km
- Minimum bending radius, occasionally moving: 8 (xD)
- Minimum bending radius, fixed installation: 4 (xD)
LiHCH 4x0,75
Nexans ref.
- Packaging: m (1000m)
- Construction type: 4 x 0.75
- Insulation colour: Black numbered
- Number of cores: 4
- Conductor cross-section: 0.75 mm²
- Diameter over braid: 5.2 mm
- Nominal diameter: 6.9 inches
- Copper content: 50 kg/km
- Max. DC resistance of the conductor at 20°C: 26 Ohm/km
- Minimum bending radius, occasionally moving: 8 (xD)
- Minimum bending radius, fixed installation: 4 (xD)
LiHCH 4x2x0,34
Nexans ref.
- Packaging: m (1000m)
- Construction type: 4 x 2 x 0.34
- Insulation colour: DIN 47100
- Number of cores: 8
- Conductor cross-section: 0.34 mm²
- Diameter over braid: 6.3 mm
- Nominal diameter: 8.2 inches
- Copper content: 70 kg/km
- Max. DC resistance of the conductor at 20°C: 57 Ohm/km
- Minimum bending radius, occasionally moving: 10 (xD)
- Minimum bending radius, fixed installation: 10 (xD)
LiHCH 4G1,5
Nexans ref.
- Packaging: m (1000m)
- Construction type: 4G1,5
- Insulation colour: Black numbered Yellow/Green
- Number of cores: 4
- Conductor cross-section: 1.5 mm²
- Diameter over braid: 6.2 mm
- Nominal diameter: 8.2 inches
- Copper content: 158 kg/km
- Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
- Minimum bending radius, occasionally moving: 8 (xD)
- Minimum bending radius, fixed installation: 4 (xD)
LiHCH 5G2,5
Nexans ref.
- Packaging: m (1000m)
- Construction type: 5G2,5
- Insulation colour: Black numbered Yellow/Green
- Number of cores: 5
- Conductor cross-section: 2.5 mm²
- Diameter over braid: 8.9 mm
- Nominal diameter: 10.9 inches
- Copper content: 390 kg/km
- Max. DC resistance of the conductor at 20°C: 7.9 Ohm/km
- Minimum bending radius, occasionally moving: 8 (xD)
- Minimum bending radius, fixed installation: 4 (xD)
LiHCH 6x1,0
Nexans ref.
- Packaging: m (1000m)
- Construction type: 6 x 1.0
- Insulation colour: Black numbered
- Number of cores: 6
- Conductor cross-section: 1 mm²
- Diameter over braid: 6.6 mm
- Nominal diameter: 8.5 inches
- Copper content: 63 kg/km
- Max. DC resistance of the conductor at 20°C: 19.5 Ohm/km
- Minimum bending radius, occasionally moving: 20 (xD)
- Minimum bending radius, fixed installation: 10 (xD)
LiHCH 6x2x0,34
Nexans ref.
- Packaging: m (1000m)
- Construction type: 6 x 2 x 0.34
- Insulation colour: DIN 47100
- Number of cores: 12
- Conductor cross-section: 0.34 mm²
- Diameter over braid: 7.6 mm
- Nominal diameter: 9.5 inches
- Copper content: 88 kg/km
- Max. DC resistance of the conductor at 20°C: 57 Ohm/km
- Minimum bending radius, occasionally moving: 10 (xD)
- Minimum bending radius, fixed installation: 10 (xD)
LiHCH 7x1,0
Nexans ref.
- Packaging: m (1000m)
- Construction type: 7 x 1.0
- Insulation colour: Black numbered
- Number of cores: 7
- Conductor cross-section: 1 mm²
- Diameter over braid: 6.6 mm
- Nominal diameter: 8.5 inches
- Copper content: 63 kg/km
- Max. DC resistance of the conductor at 20°C: 19.5 Ohm/km
- Minimum bending radius, occasionally moving: 20 (xD)
- Minimum bending radius, fixed installation: 10 (xD)
LiHCH 7x0,25
Nexans ref.
- Packaging: m (1000m)
- Construction type: 7x0,25
- Insulation colour: DIN 47100
- Number of cores: 7
- Conductor cross-section: 0.25 mm²
- Diameter over braid: 4.3 mm
- Nominal diameter: 6 inches
- Copper content: 390 kg/km
- Max. DC resistance of the conductor at 20°C: 79 Ohm/km
- Minimum bending radius, occasionally moving: 10 (xD)
- Minimum bending radius, fixed installation: 10 (xD)
LiHCH 4x0.50
Nexans ref.
- Packaging: m (1000m)
- Construction type: 7x0,25
- Insulation colour: DIN 47100
- Number of cores: 4
- Conductor cross-section: 0.5 mm²
- Diameter over braid: 4.6 mm
- Nominal diameter: 6.4 inches
- Copper content: 137 kg/km
- Max. DC resistance of the conductor at 20°C: 39 Ohm/km
- Minimum bending radius, occasionally moving: 10 (xD)
- Minimum bending radius, fixed installation: 10 (xD)
Description
Description
Standards
-
ProductNexans specification
Application
The cable WINDLINK® Control LSOH shielded was specifically designed for wind turbines. These cable is used where high flexibility, torsion- and oil-resistance are required. It is therefore a suitable connection for electrical equipments.
Product characteristics
- Suitable for torsion up to ± 150°/m (from -20°C up to 50°C)
- Vibration resistant
- Low smoke according to IEC 61034-2
- Flame retardant according to IEC 60332-1
- Oil resistant according to EN 60811-2-1 and special oils used in wind turbines
- Halogen free according to IEC 60754
- UV resistant according to IEC 60068-2-5
- Ozone resistant according to EN 60811-2-1 clause 8
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Bare copper class 5
Insulation
Halogen free compound
Screen
Tinned copper braid, coverage ≥ 80%
Outer sheath
Halogen free compound
Sheath colour
Black - RAL 9005
Electrical characteristics
Electrical characteristics
Max. Electrical Resistance AC 60Hz 70°C
- Ohm/km
Max. Electrical Resistance AC 60Hz 90°C
- Ohm/km
Insulation resistance at 20°C
100 MOhm.km
Operating capacitances
- mF/km
Rated Voltage Uo/U (Um)
300/500 V
Test voltage
1500 V
Transfer impedance
10
Mechanical characteristics
Mechanical characteristics
Torsion stress
100 °/m
Usage characteristics
Usage characteristics
Gases corrosivity
IEC 60754-2
Fire retardant
IEC 60332-1-2
Oil resistance
EN 60811-2-1
Smoke density
IEC 61034-2
U.V resistance
IEC 60068-2-5
Ozone resistance
EN 60811-2-1
Ambient installation temperature
- °C
Ambient dynamic operating temperature, range
-30 ... 80 °C
Ambient static operating temperature, range
-40 ... 80 °C