WINDLINK® Control LiHCH LSOH shielded

Products

LiHCH 10x1,0

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 10 x 1.0
  • Insulation colour: Black numbered
  • Number of cores: 10
  • Conductor cross-section: 1 mm²
  • Diameter over braid: 8.8 mm
  • Nominal diameter: 10.7 inches
  • Copper content: 78 kg/km
  • Max. DC resistance of the conductor at 20°C: 19.5 Ohm/km
  • Minimum bending radius, occasionally moving: 20 (xD)
  • Minimum bending radius, fixed installation: 10 (xD)

 

LiHCH 12G1,0

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 12 G 1.0
  • Insulation colour: Black numbered Yellow/Green
  • Number of cores: 12
  • Conductor cross-section: 1 mm²
  • Diameter over braid: 9.1 mm
  • Nominal diameter: 11.1 inches
  • Copper content: 98 kg/km
  • Max. DC resistance of the conductor at 20°C: 19.5 Ohm/km
  • Minimum bending radius, occasionally moving: 20 (xD)
  • Minimum bending radius, fixed installation: 10 (xD)

 

LiHCH 12x1,5

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 12 x 1.5
  • Insulation colour: Black numbered
  • Number of cores: 12
  • Conductor cross-section: 1.5 mm²
  • Diameter over braid: 10.4 mm
  • Nominal diameter: 13 inches
  • Copper content: 294 kg/km
  • Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
  • Minimum bending radius, occasionally moving: 8 (xD)
  • Minimum bending radius, fixed installation: 4 (xD)

 

LiHCH 16x0,34

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 16x0,34
  • Insulation colour: DIN 47100
  • Number of cores: 16
  • Conductor cross-section: 0.34 mm²
  • Diameter over braid: 7.4 mm
  • Nominal diameter: 9.3 inches
  • Copper content: 58 kg/km
  • Max. DC resistance of the conductor at 20°C: 57 Ohm/km
  • Minimum bending radius, occasionally moving: 10 (xD)
  • Minimum bending radius, fixed installation: 10 (xD)

 

LiHCH 2x0,75

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 2 x 0.75
  • Insulation colour: DIN 47100
  • Number of cores: 2
  • Conductor cross-section: 0.75 mm²
  • Diameter over braid: 4.4 mm
  • Nominal diameter: 6 inches
  • Copper content: 40 kg/km
  • Max. DC resistance of the conductor at 20°C: 26 Ohm/km
  • Minimum bending radius, occasionally moving: 20 (xD)
  • Minimum bending radius, fixed installation: 10 (xD)

 

LiHCH 2x0,50

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 2x0,50
  • Insulation colour: DIN 47100
  • Number of cores: 2
  • Conductor cross-section: 0.5 mm²
  • Diameter over braid: 4.0 mm
  • Nominal diameter: 5.6 inches
  • Copper content: 107 kg/km
  • Max. DC resistance of the conductor at 20°C: 39 Ohm/km
  • Minimum bending radius, occasionally moving: 10 (xD)
  • Minimum bending radius, fixed installation: 10 (xD)

 

LiHCH 2x1,5

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 2x1,5
  • Insulation colour: Black numbered
  • Number of cores: 2
  • Conductor cross-section: 1.5 mm²
  • Diameter over braid: 5.3 mm
  • Nominal diameter: 7.1 inches
  • Copper content: 98 kg/km
  • Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
  • Minimum bending radius, occasionally moving: 20 (xD)
  • Minimum bending radius, fixed installation: 10 (xD)

 

LiHCH 3x2x0,34

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 3 x 2 x 0.34
  • Insulation colour: DIN 47100
  • Number of cores: 6
  • Conductor cross-section: 0.34 mm²
  • Diameter over braid: 5.8 mm
  • Nominal diameter: 7.6 inches
  • Copper content: 70 kg/km
  • Max. DC resistance of the conductor at 20°C: 57 Ohm/km
  • Minimum bending radius, occasionally moving: 10 (xD)
  • Minimum bending radius, fixed installation: 10 (xD)

 

LiHCH 3x2x0,50

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 3 x 2 x 0.50
  • Insulation colour: DIN 47100
  • Number of cores: 6
  • Conductor cross-section: 0.5 mm²
  • Diameter over braid: 6.6 mm
  • Nominal diameter: 8.4 inches
  • Copper content: 137 kg/km
  • Max. DC resistance of the conductor at 20°C: 39 Ohm/km
  • Minimum bending radius, occasionally moving: 10 (xD)
  • Minimum bending radius, fixed installation: 10 (xD)

 

LiHCH 3G0,75

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 3G0,75
  • Insulation colour: Brown - Light blue - Green/yellow.
  • Number of cores: 3
  • Conductor cross-section: 0.75 mm²
  • Diameter over braid: 4.6 mm
  • Nominal diameter: 6.3 inches
  • Copper content: 50 kg/km
  • Max. DC resistance of the conductor at 20°C: 26 Ohm/km
  • Minimum bending radius, occasionally moving: 8 (xD)
  • Minimum bending radius, fixed installation: 8 (xD)

 

LiHCH 3G1,5

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 3G1,5
  • Insulation colour: Black numbered Yellow/Green
  • Number of cores: 3
  • Conductor cross-section: 1.5 mm²
  • Diameter over braid: 5.6 mm
  • Nominal diameter: 7.4 inches
  • Copper content: 158 kg/km
  • Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
  • Minimum bending radius, occasionally moving: 20 (xD)
  • Minimum bending radius, fixed installation: 10 (xD)

 

LiHCH 3G6

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 3G6
  • Insulation colour: Black numbered Yellow/Green
  • Number of cores: 3
  • Conductor cross-section: 6 mm²
  • Diameter over braid: 9.7 mm
  • Nominal diameter: 12.1 inches
  • Copper content: - kg/km
  • Max. DC resistance of the conductor at 20°C: 3.3 Ohm/km
  • Minimum bending radius, occasionally moving: 8 (xD)
  • Minimum bending radius, fixed installation: 4 (xD)

 

LiHCH 4x0,75

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 4 x 0.75
  • Insulation colour: Black numbered
  • Number of cores: 4
  • Conductor cross-section: 0.75 mm²
  • Diameter over braid: 5.2 mm
  • Nominal diameter: 6.9 inches
  • Copper content: 50 kg/km
  • Max. DC resistance of the conductor at 20°C: 26 Ohm/km
  • Minimum bending radius, occasionally moving: 8 (xD)
  • Minimum bending radius, fixed installation: 4 (xD)

 

LiHCH 4x2x0,34

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 4 x 2 x 0.34
  • Insulation colour: DIN 47100
  • Number of cores: 8
  • Conductor cross-section: 0.34 mm²
  • Diameter over braid: 6.3 mm
  • Nominal diameter: 8.2 inches
  • Copper content: 70 kg/km
  • Max. DC resistance of the conductor at 20°C: 57 Ohm/km
  • Minimum bending radius, occasionally moving: 10 (xD)
  • Minimum bending radius, fixed installation: 10 (xD)

 

LiHCH 4G1,5

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 4G1,5
  • Insulation colour: Black numbered Yellow/Green
  • Number of cores: 4
  • Conductor cross-section: 1.5 mm²
  • Diameter over braid: 6.2 mm
  • Nominal diameter: 8.2 inches
  • Copper content: 158 kg/km
  • Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
  • Minimum bending radius, occasionally moving: 8 (xD)
  • Minimum bending radius, fixed installation: 4 (xD)

 

LiHCH 5G2,5

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 5G2,5
  • Insulation colour: Black numbered Yellow/Green
  • Number of cores: 5
  • Conductor cross-section: 2.5 mm²
  • Diameter over braid: 8.9 mm
  • Nominal diameter: 10.9 inches
  • Copper content: 390 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.9 Ohm/km
  • Minimum bending radius, occasionally moving: 8 (xD)
  • Minimum bending radius, fixed installation: 4 (xD)

 

LiHCH 6x1,0

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 6 x 1.0
  • Insulation colour: Black numbered
  • Number of cores: 6
  • Conductor cross-section: 1 mm²
  • Diameter over braid: 6.6 mm
  • Nominal diameter: 8.5 inches
  • Copper content: 63 kg/km
  • Max. DC resistance of the conductor at 20°C: 19.5 Ohm/km
  • Minimum bending radius, occasionally moving: 20 (xD)
  • Minimum bending radius, fixed installation: 10 (xD)

 

LiHCH 6x2x0,34

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 6 x 2 x 0.34
  • Insulation colour: DIN 47100
  • Number of cores: 12
  • Conductor cross-section: 0.34 mm²
  • Diameter over braid: 7.6 mm
  • Nominal diameter: 9.5 inches
  • Copper content: 88 kg/km
  • Max. DC resistance of the conductor at 20°C: 57 Ohm/km
  • Minimum bending radius, occasionally moving: 10 (xD)
  • Minimum bending radius, fixed installation: 10 (xD)

 

LiHCH 7x1,0

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 7 x 1.0
  • Insulation colour: Black numbered
  • Number of cores: 7
  • Conductor cross-section: 1 mm²
  • Diameter over braid: 6.6 mm
  • Nominal diameter: 8.5 inches
  • Copper content: 63 kg/km
  • Max. DC resistance of the conductor at 20°C: 19.5 Ohm/km
  • Minimum bending radius, occasionally moving: 20 (xD)
  • Minimum bending radius, fixed installation: 10 (xD)

 

LiHCH 7x0,25

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 7x0,25
  • Insulation colour: DIN 47100
  • Number of cores: 7
  • Conductor cross-section: 0.25 mm²
  • Diameter over braid: 4.3 mm
  • Nominal diameter: 6 inches
  • Copper content: 390 kg/km
  • Max. DC resistance of the conductor at 20°C: 79 Ohm/km
  • Minimum bending radius, occasionally moving: 10 (xD)
  • Minimum bending radius, fixed installation: 10 (xD)

 

LiHCH 4x0.50

Nexans ref.

  • Packaging: m (1000m)
  • Construction type: 7x0,25
  • Insulation colour: DIN 47100
  • Number of cores: 4
  • Conductor cross-section: 0.5 mm²
  • Diameter over braid: 4.6 mm
  • Nominal diameter: 6.4 inches
  • Copper content: 137 kg/km
  • Max. DC resistance of the conductor at 20°C: 39 Ohm/km
  • Minimum bending radius, occasionally moving: 10 (xD)
  • Minimum bending radius, fixed installation: 10 (xD)

 

Description

Description

Standards

  • Product
    Nexans specification

Application
The cable WINDLINK® Control LSOH shielded was specifically designed for wind turbines. These cable is used where high flexibility, torsion- and oil-resistance are required. It is therefore a suitable connection for electrical equipments.

Product characteristics

  • Suitable for torsion up to ± 150°/m (from -20°C up to 50°C) 
  • Vibration resistant
  • Low smoke according to IEC 61034-2
  • Flame retardant according to IEC 60332-1
  • Oil resistant according to EN 60811-2-1 and special oils used in wind turbines
  • Halogen free according to IEC 60754
  • UV resistant according to IEC 60068-2-5
  • Ozone resistant according to EN 60811-2-1 clause 8

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Bare copper class 5
Insulation
Halogen free compound
Screen
Tinned copper braid, coverage ≥ 80%
Outer sheath
Halogen free compound
Sheath colour
Black - RAL 9005

Electrical characteristics

Electrical characteristics

Max. Electrical Resistance AC 60Hz 70°C
- Ohm/km
Max. Electrical Resistance AC 60Hz 90°C
- Ohm/km
Insulation resistance at 20°C
100 MOhm.km
Operating capacitances
- mF/km
Rated Voltage Uo/U (Um)
300/500 V
Test voltage
1500 V
Transfer impedance
10

Mechanical characteristics

Mechanical characteristics

Torsion stress
100 °/m

Usage characteristics

Usage characteristics

Gases corrosivity
IEC 60754-2
Fire retardant
IEC 60332-1-2
Oil resistance
EN 60811-2-1
Smoke density
IEC 61034-2
U.V resistance
IEC 60068-2-5
Ozone resistance
EN 60811-2-1
Ambient installation temperature
- °C
Ambient dynamic operating temperature, range
-30 ... 80 °C
Ambient static operating temperature, range
-40 ... 80 °C

Resources

Resources

Documentation

xls — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close