EN 2267-010A DR
EN 2267-010A DR
Designed for general Purpose Aircraft Wiring Applications.
UV Laser printable Wire
260°C Operating Temperature Light Weight
Arc Tracking Resistant
EN 2267-010A 001
Nexans ref.
- Type of conductor: Stranded Conductor: Nickel plated high Strength copper alloy
- Conductor cross-section (AWG/KCMIL): 26
- Conductor stranding: 19 x 0.10
- minimum core diameter: 0.47 mm
- Maximum core diameter: 0.49 mm
- Minimum cable diameter: 0.75 mm
- Maximum outer diameter: 0.84 mm
- Nominal weight: 1.95 g/m
- Maximum weight: 2.08 g/m
EN 2267-010A 002
Nexans ref.
- Type of conductor: Stranded Conductor: Nickel plated high Strength copper alloy
- Conductor cross-section (AWG/KCMIL): 24
- Conductor stranding: 19 x 0.12
- minimum core diameter: 0.56 mm
- Maximum core diameter: 0.58 mm
- Minimum cable diameter: 0.85 mm
- Maximum outer diameter: 0.96 mm
- Nominal weight: 2.64 g/m
- Maximum weight: 2.72 g/m
EN 2267-010A 004
Nexans ref.
- Type of conductor: Stranded Conductor: Nickel plated alloy
- Conductor cross-section (AWG/KCMIL): 22
- Conductor stranding: 19 x 0.15
- minimum core diameter: 0.71 mm
- Maximum core diameter: 0.73 mm
- Minimum cable diameter: 1 mm
- Maximum outer diameter: 1.1 mm
- Nominal weight: 3.89 g/m
- Maximum weight: 4.14 g/m
EN 2267-010A 006
Nexans ref.
- Type of conductor: Stranded Conductor: Nickel plated alloy
- Conductor cross-section (AWG/KCMIL): 20
- Conductor stranding: 19 x 0.20
- minimum core diameter: 0.94 mm
- Maximum core diameter: 0.97 mm
- Minimum cable diameter: 1.22 mm
- Maximum outer diameter: 1.34 mm
- Nominal weight: 6.57 g/m
- Maximum weight: 6.85 g/m
EN 2267-010A 010
Nexans ref.
- Type of conductor: Stranded Conductor: Nickel plated alloy
- Conductor cross-section (AWG/KCMIL): 16
- Conductor stranding: 19 x 0.25
- minimum core diameter: 1.19 mm
- Maximum core diameter: 1.22 mm
- Minimum cable diameter: 1.46 mm
- Maximum outer diameter: 1.61 mm
- Nominal weight: 10.15 g/m
- Maximum weight: 10.43 g/m
EN 2267-010A 012
Nexans ref.
- Type of conductor: Stranded Conductor: Nickel plated alloy
- Conductor cross-section (AWG/KCMIL): 18
- Conductor stranding: 19 x 0.30
- minimum core diameter: 1.41 mm
- Maximum core diameter: 1.45 mm
- Minimum cable diameter: 1.76 mm
- Maximum outer diameter: 1.92 mm
- Nominal weight: 14.05 g/m
- Maximum weight: 14.61 g/m
EN 2267-010A 020
Nexans ref.
- Type of conductor: Stranded Conductor: Nickel plated alloy
- Conductor cross-section (AWG/KCMIL): 14
- Conductor stranding: 37 x 0.25
- minimum core diameter: 1.69 mm
- Maximum core diameter: 1.73 mm
- Minimum cable diameter: 2.04 mm
- Maximum outer diameter: 2.24 mm
- Nominal weight: 19.31 g/m
- Maximum weight: 19.78 g/m
EN 2267-010A 030
Nexans ref.
- Type of conductor: Stranded Conductor: Nickel plated alloy
- Conductor cross-section (AWG/KCMIL): 12
- Conductor stranding: 37 x 0.32
- minimum core diameter: 2.13 mm
- Maximum core diameter: 2.18 mm
- Minimum cable diameter: 2.5 mm
- Maximum outer diameter: 2.7 mm
- Nominal weight: 29.25 g/m
- Maximum weight: 31.33 g/m
EN 2267-010A 051
Nexans ref.
- Type of conductor: Stranded Conductor: Nickel plated alloy
- Conductor cross-section (AWG/KCMIL): 10
- Conductor stranding: 61 x 0.32
- minimum core diameter: 2.73 mm
- Maximum core diameter: 2.77 mm
- Minimum cable diameter: 3.13 mm
- Maximum outer diameter: 3.33 mm
- Nominal weight: 47.37 g/m
- Maximum weight: 49.85 g/m
EN 2267-010A 090
Nexans ref.
- Type of conductor: Stranded Conductor: Nickel plated alloy
- Conductor cross-section (AWG/KCMIL): 8
- Conductor stranding: 127 x 0.30
- minimum core diameter: 3.55 mm
- Maximum core diameter: 3.85 mm
- Minimum cable diameter: 4.1 mm
- Maximum outer diameter: 4.4 mm
- Nominal weight: 87.81 g/m
- Maximum weight: 90 g/m
EN 2267-010A 140
Nexans ref.
- Type of conductor: Stranded Conductor: Nickel plated alloy
- Conductor cross-section (AWG/KCMIL): 6
- Conductor stranding: 27 x 7 x 0.30
- minimum core diameter: 4.8 mm
- Maximum core diameter: 5.2 mm
- Minimum cable diameter: 5.3 mm
- Maximum outer diameter: 5.7 mm
- Nominal weight: 132.41 g/m
- Maximum weight: 135 g/m
EN 2267-010A 220
Nexans ref.
- Type of conductor: Stranded Conductor: Nickel plated alloy
- Conductor cross-section (AWG/KCMIL): 4
- Conductor stranding: 37 x 12 x 0.25
- minimum core diameter: - mm
- Maximum core diameter: 6.8 mm
- Minimum cable diameter: 6.71 mm
- Maximum outer diameter: 7.41 mm
- Nominal weight: 215.15 g/m
- Maximum weight: 222 g/m
EN 2267-010A 340
Nexans ref.
- Type of conductor: Stranded Conductor: Nickel plated alloy
- Conductor cross-section (AWG/KCMIL): 2
- Conductor stranding: 37 x 19 x 0.25
- minimum core diameter: - mm
- Maximum core diameter: 8.6 mm
- Minimum cable diameter: 8.28 mm
- Maximum outer diameter: 9.16 mm
- Nominal weight: 336.1 g/m
- Maximum weight: 347 g/m
Description
Description
Standards
-
ProductEN 2267-010
Design Construction
1-Core
Stranded Conductor : Nickel Plated High
Strength Copper Alloy (AWG 26 & 24) or
Nickel Plated Copper (AWG 22 to 2)
2-Insulation
Special Polyimide Tape
Special UV PTFE Tape(s)
IDENTIFICATION
Standard colour code :
White except AWG 26 which is light yellow and AWG 22 which is light green
AWG 24 is available in light blue color (EN2267-010A 002B)
Color of marking: green
Marking text: EN DR ** FR F ++
DR = Short designation
** = AWG Wire Size
FR = Country of origin (FR = France)
F = Manufacturer (F = Nexans)
++ = Year of production (i.e. 13 = 2013)
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania