SCNV-S 6x1,0²

Description

Description

Standards

  • Product
    IEC 60228

Application

Single-core and multi-core cables for railway applications intended for connecting equipment on and near the tracks. Lynxeo's cables are designed to allow ease of stripping, facilitating the installation process particularly the intergation with connectors and measurement systems.  

An example of an application is the connection of CAUTOR, FORFEX or PAULVÉ electromechanical detectors, which detect the passage of a train on the track and even its direction. They can also control any function linked to this passage, such as level crossings, signal control and station point control.

Lynxeo SCN-S and SCNV-S cables are adapted to fit with reinforced copper die-cast lugs designed for railways applications according to SNCF specifications.

 

Design

 1. Conductor
    Flexible tinned copper Class 5 according to IEC 60228
    Separator (optional)

 2. Insulation
    Cross-linked elastomer

      Color coding
        - 1 core: white
        - 4 cores: black, blue, yellow, red
        - 6 or 8 cores: numbers on black cores
    Separator (optional)

 3. Outer sheath
    Cross-linked elastomer
    Color: black

Example of marking: 
SCN-S - x mm² - CT 451 LYNXEO 269 YY-MM        xxx m
or SCNV-S - x mm² - CT 451 LYNXEO 269 YY-MM        xxx m

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Flexible class 5
Conductor material
Tin plated copper
Insulation
Cross-linked compound
Number of conductors
6
Outer sheath
Cross-linked compound

Dimensional characteristics

Dimensional characteristics

Approximate weight
337 kg/km
Conductor cross-section
1 mm²
Maximum outer diameter
17.0 mm
Minimum outer diameter
16.0 mm
Nominal conductor diameter
1.3 mm
Nominal outer diameter
3.0 mm

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
450/750 V
Maximum DC resistance at 20°C
20 Ohm/100m

Usage characteristics

Usage characteristics

Flame retardant
C2, NF C 32-070 & IEC 60332-1
Oil resistance
Good
U.V resistance
Good
Max. conductor temperature in service
70 °C
Operating temperature, range
-30 ... 65 °C

Resources

Resources

Documentation

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close