NF F55-625 (K25) 1 core 750V Cl1 or Cl2 CPR B2ca-s1a, d0, a1
NF F55-625 (K25) 1 core 750V Cl1 or Cl2 CPR B2ca-s1a, d0, a1
NF F 55-625 (K25) 750V - 1x1 CL1 noir
Nexans ref. 10270843
- Conductor cross-section: 1 mm²
- Maximum outer diameter: 3.1 mm
- Approximate weight: 18 kg/km
NF F 55-625 (K25) 750V - 1x1,5 CL1 blanc
Nexans ref.
- Conductor cross-section: 1.5 mm²
- Maximum outer diameter: 3.3 mm
- Approximate weight: 20 kg/km
NF F 55-625 (K25) 750V - 1x1,5 CL1 bleu
Nexans ref. 10277929
- Conductor cross-section: 1.5 mm²
- Maximum outer diameter: 3.3 mm
- Approximate weight: 20 kg/km
NF F 55-625 (K25) 750V - 1x1,5 CL1 brun
Nexans ref. 10277931
- Conductor cross-section: 1.5 mm²
- Maximum outer diameter: 3.3 mm
- Approximate weight: 20 kg/km
NF F 55-625 (K25) 750V - 1x1,5 CL1 noir
Nexans ref. 10276514
- Conductor cross-section: 1.5 mm²
- Maximum outer diameter: 3.3 mm
- Approximate weight: 20 kg/km
NF F 55-625 (K25) 750V - 1x1,5 CL1 rouge
Nexans ref. 10277930
- Conductor cross-section: 1.5 mm²
- Maximum outer diameter: 3.3 mm
- Approximate weight: 20 kg/km
NF F 55-625 (K25) 750V - 1x1,5 CL1 vert/jaune
Nexans ref. 10276491
- Conductor cross-section: 1.5 mm²
- Maximum outer diameter: 3.3 mm
- Approximate weight: 20 kg/km
NF F 55-625 (K25) 750V - 1x2,5 CL1 blanc
Nexans ref.
- Conductor cross-section: 2.5 mm²
- Maximum outer diameter: 3.9 mm
- Approximate weight: 35 kg/km
NF F 55-625 (K25) 750V - 1x2,5 CL1 bleu
Nexans ref. 10277932
- Conductor cross-section: 2.5 mm²
- Maximum outer diameter: 3.9 mm
- Approximate weight: 35 kg/km
NF F 55-625 (K25) 750V - 1x2,5 CL1 brun
Nexans ref. 10277934
- Conductor cross-section: 2.5 mm²
- Maximum outer diameter: 3.9 mm
- Approximate weight: 35 kg/km
NF F 55-625 (K25) 750V - 1x2,5 CL1 noir
Nexans ref. 10276515
- Conductor cross-section: 2.5 mm²
- Maximum outer diameter: 3.9 mm
- Approximate weight: 35 kg/km
NF F 55-625 (K25) 750V - 1x2,5 CL1 rouge
Nexans ref. 10277933
- Conductor cross-section: 2.5 mm²
- Maximum outer diameter: 3.9 mm
- Approximate weight: 35 kg/km
NF F 55-625 (K25) 750V - 1x2,5 CL1 vert/jaune
Nexans ref. 10276492
- Conductor cross-section: 2.5 mm²
- Maximum outer diameter: 3.9 mm
- Approximate weight: 35 kg/km
NF F 55-625 (K25) 750V - 1x4 CL1 blanc
Nexans ref.
- Conductor cross-section: 4 mm²
- Maximum outer diameter: 4.4 mm
- Approximate weight: 50 kg/km
NF F 55-625 (K25) 750V - 1x4 CL1 bleu
Nexans ref. 10277935
- Conductor cross-section: 4 mm²
- Maximum outer diameter: 4.4 mm
- Approximate weight: 50 kg/km
NF F 55-625 (K25) 750V - 1x4 CL1 brun
Nexans ref. 10277937
- Conductor cross-section: 4 mm²
- Maximum outer diameter: 4.4 mm
- Approximate weight: 50 kg/km
NF F 55-625 (K25) 750V - 1x4 CL1 noir
Nexans ref. 10276516
- Conductor cross-section: 4 mm²
- Maximum outer diameter: 4.4 mm
- Approximate weight: 50 kg/km
NF F 55-625 (K25) 750V - 1x4 CL1 rouge
Nexans ref.
- Conductor cross-section: 4 mm²
- Maximum outer diameter: 4.4 mm
- Approximate weight: 50 kg/km
NF F 55-625 (K25) 750V - 1x4 CL1 vert/jaune
Nexans ref. 10276493
- Conductor cross-section: 4 mm²
- Maximum outer diameter: 4.4 mm
- Approximate weight: 50 kg/km
NF F 55-625 (K25) 750V - 1x4 CL2 blanc
Nexans ref.
- Conductor cross-section: 4 mm²
- Maximum outer diameter: 4.8 mm
- Approximate weight: 50 kg/km
NF F 55-625 (K25) 750V - 1x4 CL2 bleu
Nexans ref.
- Conductor cross-section: 4 mm²
- Maximum outer diameter: 4.8 mm
- Approximate weight: 50 kg/km
NF F 55-625 (K25) 750V - 1x4 CL2 brun
Nexans ref.
- Conductor cross-section: 4 mm²
- Maximum outer diameter: 4.8 mm
- Approximate weight: 50 kg/km
NF F 55-625 (K25) 750V - 1x4 CL2 noir
Nexans ref.
- Conductor cross-section: 4 mm²
- Maximum outer diameter: 4.8 mm
- Approximate weight: 50 kg/km
NF F 55-625 (K25) 750V - 1x4 CL2 rouge
Nexans ref.
- Conductor cross-section: 4 mm²
- Maximum outer diameter: 4.8 mm
- Approximate weight: 50 kg/km
NF F 55-625 (K25) 750V - 1x4 CL2 vert/jaune
Nexans ref.
- Conductor cross-section: 4 mm²
- Maximum outer diameter: 4.8 mm
- Approximate weight: 50 kg/km
Description
Description
Standards
-
ProductEN 50575; IEC 60228
-
InstallationNF F 55-625
Application
These cables are used for fixed power or lighting installations in tunnels and underground stations.
Fire performance
- Flame retardant: according to RATP K20 specification
- Fire retardant: according to RATP K20 specification
- Low smoke: according to RATP K20 specification
- Low toxicity: According to RATP K20 specification
- Low corrosivity: According to RATP K20 specification
- Without Halogen : According to RATP K20 specification
Reaction to fire: B2ca-s1a, d0, a1
Design
- Conductor: Bare copper class 1 or class 2
- Insulation: Polyolefin without halogen
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Selling & delivery Information
Marking
750 - Nber of cores & cross-section - SH -NF F 55-625 - NEXANS 279 - WW - YY - B2ca-s1a, d0, a1 - Manufacturing n° - DoP:1000795-FRME + metric marking
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania