FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x4
FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x4
FLAMEX
FIRE RESISTANT POWER CABLES
FLAMEX® EN50264-3-1 FR flexible power cables maintain circuit integrity in case of fire (according to EN 50200 for 90 minutes) and are fire retardant, low smoke and halogen-free safisfying performance requirements of EN 45545-2-HL3. On top of that, FLAMEX® cables withstand tough working conditions (oil, ozone, temperature variations, etc.).
- Product ref. : 79462514
Description
Description
Standards
-
ProductEN 50264-3-1; EN 45545 - HL3; IEC 60228
-
TestEN 50200; IEC 60331-1 or 2
DESIGN
1. Conductor
Flexible stranded tinned copper, class 5 acc. to IEC 60228
Mineral tape
2. Insulation
Cross-linked compound type EI 109 acc. to EN 50264-1
Oil, diesel, ozone and UV resistant
Colour: black
Example of marking: FLAMEX type EN 50264-3-1 FR 600 V mm² M (N)MHXAF-FR 0,6/1kV
I LYNXEO I WW-YYYY
GUIDE TO USE
- Cabling rules are given in EN 50343 and EN 50355
- Permissible current carrying capacities: values and calculation method are given in EN 50343
- Bending radius:
- Static use: 3 x outer cable diameter if D ≤ 10mm / 5 x outer cable diameter if D > 10mm
- For installation and occasional movements: 10 x outer cable diameter
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Tin plated copper
Conductor flexibility
Flexible class 5
Insulation
Cross-linked compound
Halogen free
EN 60754-1 & EN 60684-2
Insulation colour
Black
Dimensional characteristics
Dimensional characteristics
Conductor cross-section
4 mm²
Minimum outer diameter
4.5 mm
Maximum outer diameter
4.9 mm
Approximate weight
46 kg/km
Conductor diameter
- mm
Electrical characteristics
Electrical characteristics
Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV
Usage characteristics
Usage characteristics
Fire resistant
IEC 60331-1 or -2
Flame retardant
IEC 60332-1-2
Fire retardant
EN IEC 60332-3-24 (cat C); EN IEC 60332-3-25 (EN50305)
Smoke density
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Operating temperature, range
-40 ... 90 °C
Max. conductor temperature in service
90 °C
Overload maximum core temperature
120 °C
Chemical resistance
Good
Ozone resistance
Yes
U.V resistance
Yes
Short-circuit max. conductor temperature
200 °C