FLAMEX 20 TYPE MSZ 1X2.5
FLAMEX 20 TYPE MSZ 1X2.5
FLAMEX
FIRE RESISTANT CONTROL WIRES
FLAMEX® Fire Resistant control wires TYPE EN 50306-2 maintain circuit integrity in case of fire (according to EN 50200 for 120 minutes) and are fire retardant, low smoke and halogenfree safisfying performance requirements of EN 45545-2 HL3. In addition, FLAMEX® cables withstand the tough working conditions of rolling stock (oil, ozone, temperature variations, etc.).
- Product ref. : 13101505
- Country ref. : 2PN303
Description
Description
Standards
-
ProductEN 45545-2 (HL3)
-
TestEN 50200; EN 50305; EN 50306; IEC 60331-2
DESIGN
1. Conductor
Flexible stranded tinned copper
2. Insulation
Mineral tape as fire barrier
Thin wall halogen-free cross-linked material acc. EN 50306-2
Colour: white
Example of marking: FLAMEX 239 - EDE 2PN299 - TYPE EN 50306-2 - EN 50200 - 300 V - 1x0.5 - M - week/year - batch number
GUIDE TO USE
- Cabling rules are given in EN 50343 and EN 50355
- Permissible current carrying capacities: values and calculation method are given in EN 50343
- Bending radius:
- Static use: 5 x outer cable diameter
- For installation and occasional movements: 10 x outer cable diameter
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Tin plated copper
Conductor flexibility
Flexible stranded
Insulation
Cross-linked compound
Halogen free
EN 60754-1 & EN 60684-2
Insulation colour
White
Dimensional characteristics
Dimensional characteristics
Conductor cross-section
2.5 mm²
Stranding (No./mm)
Conductor diameter (mm)
2.00
Minimum cable diameter
2.9 mm
Maximum cable diameter
3.3 mm
Approximate weight
27.6 kg/km
Electrical characteristics
Electrical characteristics
Rated Voltage Uo/U (Um)
300 / 300 V
Max. DC resistance of the conductor at 20°C
8.21 Ohm/km
Usage characteristics
Usage characteristics
Fire resistant
-
Flame retardant
EN 60332-1-2
Fire retardant
EN IEC 60332-3-25 (EN50305)
Smoke density
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Operating temperature, range
-40 ... 105 °C
Maximum operating temperature
105 °C
Overload maximum core temperature
125 °C
Chemical resistance
Excellent
Fire load
0.027 kWh/m