TCX (C) 150/250V 1x3x1.5

Description

Description

Standards

  • Installation
    IEC 60092-350; IEC 60092-351; IEC 60092-359; IEC 60092-376
  • Test
    IEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
  • International
    IEC 60298

Application

TCX® (C) type is used on board of ships in all locations for installations complying with IEC standards 60092-352. For open decks installation, cables have to be covered against UV rays. TCX® (C) type withstands IEC 60332-3-22 fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire.

Design

  1. Conductor
    Stranded bare copper  class 2
     
  2. Insulation
    XLPE (cross linked polyethylene)
     
  3. Inner covering
    Polyester tape
     
  4. Armouring
    Bare copper braid with a bare copper drain wire
     
  5. Outer sheath
    Polyolefin SHF1 (SHF2 on request)
    Colour : orange

 

*Note: 2 pairs assembled as a quad

 

Core Identification

Core 1: white + printed number

Core 2: blue + printed number

Core 3: red + printed number

Marking

NEXANS 448 TCX (C) «voltage» «n» x 2 «or» 3 x «s» mm2 90C IEC 60332-3-22 «WW/YY» * CE * + Metric Marking

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Halogen free
IEC 60754-1
Conductor material
Bare copper
Conductor flexibility
Stranded class 2
Insulation
XLPE (Cross-linked Polyethylene)
Inner covering
Polyester tape(s)
Armour type
Bare copper braid
Outer sheath
Polyolefin
Sheath colour
Orange

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
1.5 mm²
Minimum outer diameter
9.0 mm
Nominal outer diameter
9.4 mm
Maximum outer diameter
10.5 mm
Approximate weight
140 kg/km
Number of pairs
-
Number of triples
1

Electrical characteristics

Electrical characteristics

Max. DC resistance of the conductor at 20°C
25.6 Ohm/km
Rated Voltage Uo/U (Um)
150 / 250 (300) V

Usage characteristics

Usage characteristics

Electro magnetic interference resistance
Yes
Smoke density
IEC 61034
Fire retardant
EN IEC 60332-3-22 (cat A)
Gases corrosivity
IEC 60754-2
Operating temperature, range
-30 ... 80 °C
Max. conductor temperature in service
90 °C
Standard
IEC

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close