TCX® (I) 331 150/250 (300)V

Products

TCX® ( I ) 331 10x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 22.5 mm
  • Nominal outer diameter: 26.1 mm
  • Maximum outer diameter: 29.8 mm
  • Approximate weight: 660 kg/km

 

TCX® ( I ) 331 10x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 26.7 mm
  • Nominal outer diameter: 30.1 mm
  • Maximum outer diameter: 35.1 mm
  • Approximate weight: 920 kg/km

 

TCX® ( I ) 331 10x3x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 27.5 mm
  • Nominal outer diameter: 30.8 mm
  • Maximum outer diameter: 34.5 mm
  • Approximate weight: 850 kg/km

 

TCX® ( I ) 331 14x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 25.1 mm
  • Nominal outer diameter: 28.6 mm
  • Maximum outer diameter: 32.3 mm
  • Approximate weight: 800 kg/km

 

TCX® ( I ) 331 14x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 30.7 mm
  • Nominal outer diameter: 33.8 mm
  • Maximum outer diameter: 38.3 mm
  • Approximate weight: 1150 kg/km

 

TCX® ( I ) 331 19x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 30.0 mm
  • Nominal outer diameter: 33.2 mm
  • Maximum outer diameter: 36.5 mm
  • Approximate weight: 1030 kg/km

 

TCX® ( I ) 331 19x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 34.6 mm
  • Nominal outer diameter: 38.5 mm
  • Maximum outer diameter: 42.8 mm
  • Approximate weight: 1500 kg/km

 

TCX® ( I ) 331 1x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 9.0 mm
  • Nominal outer diameter: 9.8 mm
  • Maximum outer diameter: 11.0 mm
  • Approximate weight: 118 kg/km

 

TCX® ( I ) 331 1x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 10.0 mm
  • Nominal outer diameter: 11.0 mm
  • Maximum outer diameter: 12.5 mm
  • Approximate weight: 160 kg/km

 

TCX® ( I ) 331 1x3x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 10.0 mm
  • Nominal outer diameter: 10.6 mm
  • Maximum outer diameter: 12.0 mm
  • Approximate weight: 141 kg/km

 

TCX® ( I ) 331 1x3x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 11.0 mm
  • Nominal outer diameter: 11.6 mm
  • Maximum outer diameter: 13.0 mm
  • Approximate weight: 172 kg/km

 

TCX® ( I ) 331 24x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 34.0 mm
  • Nominal outer diameter: 38.4 mm
  • Maximum outer diameter: 42.5 mm
  • Approximate weight: 1300 kg/km

 

TCX® ( I ) 331 24x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 40.2 mm
  • Nominal outer diameter: 44.7 mm
  • Maximum outer diameter: 51.2 mm
  • Approximate weight: 1970 kg/km

 

TCX® ( I ) 331 2x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 13.0 mm
  • Nominal outer diameter: 14.5 mm
  • Maximum outer diameter: 17.1 mm
  • Approximate weight: 220 kg/km

 

TCX® ( I ) 331 2x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 14.8 mm
  • Nominal outer diameter: 16.7 mm
  • Maximum outer diameter: 19.6 mm
  • Approximate weight: 330 kg/km

 

TCX® ( I ) 331 2x3x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 14.5 mm
  • Nominal outer diameter: 16.2 mm
  • Maximum outer diameter: 19.3 mm
  • Approximate weight: 280 kg/km

 

TCX® ( I ) 331 2x3x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 16.7 mm
  • Nominal outer diameter: 18.6 mm
  • Maximum outer diameter: 21.8 mm
  • Approximate weight: 420 kg/km

 

TCX® ( I ) 331 4x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 15.2 mm
  • Nominal outer diameter: 16.8 mm
  • Maximum outer diameter: 19.6 mm
  • Approximate weight: 280 kg/km

 

TCX® ( I ) 331 4x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 17.6 mm
  • Nominal outer diameter: 20.9 mm
  • Maximum outer diameter: 24.0 mm
  • Approximate weight: 430 kg/km

 

TCX® ( I ) 331 4x3x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 17.3 mm
  • Nominal outer diameter: 19.2 mm
  • Maximum outer diameter: 21.7 mm
  • Approximate weight: 400 kg/km

 

TCX® ( I ) 331 4x3x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 19.8 mm
  • Nominal outer diameter: 22.3 mm
  • Maximum outer diameter: 25.5 mm
  • Approximate weight: 550 kg/km

 

TCX® ( I ) 331 7x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 18.7 mm
  • Nominal outer diameter: 21.6 mm
  • Maximum outer diameter: 25.5 mm
  • Approximate weight: 470 kg/km

 

TCX® ( I ) 331 7x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 21.4 mm
  • Nominal outer diameter: 24.5 mm
  • Maximum outer diameter: 27.3 mm
  • Approximate weight: 650 kg/km

 

TCX® ( I ) 331 7x3x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 21.0 mm
  • Nominal outer diameter: 24.1 mm
  • Maximum outer diameter: 28.0 mm
  • Approximate weight: 610 kg/km

 

Description

Description

Standards

  • Installation
    IEC 60092-350; IEC 60092-351; IEC 60092-359; IEC 60092-376
  • Test
    IEC 60331; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
  • International
    IEC 60298

Application

TCX®(I) 331 type is used on board of ships in all locations for installations complying with IEC standards 60092-352. For open decks installation, cables have to covered against UV rays. TCX® (I) 331 type meets IEC 60331 fire resistant performances, withstands IEC 60332-3-22 fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire.

Design

  1. Conductor:
    Bare copper
    Stranded class 2
     
  2. Insulation:
    Mica tape + XLPE
     
  3. Individual screen:
    Alu/Polyester tape with a tinned copper drain wire
     
  4. Inner covering:
    Polyester tape lapped
  5. Armouring:
    Bare copper braid with bare copper drain wire
     
  6. Outer sheath:
    Polyolefin SHF1
    Colour: orange
    SHF2 on request

Core identification
Core 1: white + printed number
Core 2: blue + printed number
Core 3: red + printed number

 

Marking

NEXANS 448 TCX (I) 331 «voltage» «n» x 2 «or» 3 x «s» mm2 90C IEC 60332-3-22 IEC 60331 «WW/YY» * CE* + Metric Marking

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Bare copper
Insulation
XLPE + Mica tape
Screen
Bare copper braid
Outer sheath
Polyolefin
Halogen free
IEC 60754-1
Protection
Polyester tape(s)

Usage characteristics

Usage characteristics

Fire retardant
EN IEC 60332-3-22 (cat A)
Smoke density
IEC 61034
Gases corrosivity
IEC 60754-2
Electro magnetic interference resistance
Yes
Fire resistant
IEC 60331-21
Max. conductor temperature in service
90 °C
Operating temperature, range
-30 ... 80 °C
Standard
IEC

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close