Description
Description
Standards
-
ProductIEC 60092-375
-
InstallationIEC 60092-3
-
TestIEC 60332-3 Cat.A; IEC 60754-1; IEC 60754-2; IEC 61034
-
InternationalIEC 60298
Application
TCX® (C) type is used on board of ships in all locations for installations complying with IEC standards 60092-352. For open decks installation, cables have to be covered against UV rays. TCX® (C) type withstands IEC 60332-3-22 fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire.
Design
- Conductor
Stranded bare copper class 2
- Insulation
XLPE (cross linked polyethylene)
- Inner covering
Polyester tape
- Armouring
Bare copper braid with a bare copper drain wire
- Outer sheath
Polyolefin SHF1 (SHF2 on request)
Colour : orange
*Note: 2 pairs assembled as a quad
Core Identification
Core 1: white + printed number
Core 2: blue + printed number
Core 3: red + printed number
Marking
NEXANS 448 TCX (C) «voltage» «n» x 2 «or» 3 x «s» mm2 90C IEC 60332-3-22 «WW/YY» * CE * + Metric Marking
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Halogen free
IEC 60754-1
Conductor material
Bare copper
Conductor flexibility
Stranded class 2
Insulation
XLPE (Cross-linked Polyethylene)
Inner covering
Polyester tape(s)
Armour type
Bare copper braid
Outer sheath
Polyolefin
Sheath colour
Orange
Dimensional characteristics
Dimensional characteristics
Conductor cross-section
0.75 mm²
Minimum outer diameter
23.0 mm
Nominal outer diameter
24.1 mm
Maximum outer diameter
26.0 mm
Approximate weight
830 kg/km
Number of pairs
24
Number of triples
-
Electrical characteristics
Electrical characteristics
Max. DC resistance of the conductor at 20°C
52 Ohm/km
Rated Voltage Uo/U (Um)
150 / 250 (300) V
Usage characteristics
Usage characteristics
Electro magnetic interference resistance
Yes
Smoke density
IEC 61034
Fire retardant
EN IEC 60332-3-22 (cat A)
Gases corrosivity
IEC 60754-2
Operating temperature, range
-30 ... 80 °C
Max. conductor temperature in service
90 °C
Standard
IEC