Description
Description
Standards
-
ProductIEC 60228
-
InstallationIEC 60092-350; IEC 60092-351; IEC 60092-359; IEC 60092-376
-
TestIEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Application
TX® (C) type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards 60092-352. TX® (C) type withstands IEC 60332-3-22 fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire.
Design
- Conductor
Stranded Bare copper class 2
- Insulation
XLPE (cross linked polyethylene)
- Collective screen
Alu/Polyester tape with a tinned copper drain wire
- Outer sheath:
Polyolefin SHF1 (SHF2 on request)
Colour : orange
*Note: 2 pairs assembled as a quad
Core Identification
Core 1: white + printed number
Core 2: blue + printed number
Core 3: red + printed number
Marking
NEXANS 448 TX (C) «voltage» «n» x 2 «or» 3 x «s» mm2 90C IEC 60332-3-22 "WW/YY" * CE * + Metric marking
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Halogen free
IEC 60754-1
Conductor material
Bare copper
Conductor flexibility
Stranded class 2
Insulation
XLPE (Cross-linked Polyethylene)
Overall screen
Aluminium/polyester tape
Drain wire
Tinned copper
Outer sheath
Polyolefin
Sheath colour
Orange
Dimensional characteristics
Dimensional characteristics
Conductor cross-section
1.5 mm²
Number of pairs
7
Number of triples
-
Minimum outer diameter
15.5 mm
Nominal outer diameter
16.4 mm
Maximum outer diameter
18.0 mm
Approximate weight
370 kg/km
Electrical characteristics
Electrical characteristics
Rated Voltage Uo/U (Um)
150 / 250 (300) V
Max. DC resistance of the conductor at 20°C
25.6 Ohm/km
Usage characteristics
Usage characteristics
Fire retardant
EN IEC 60332-3-22 (cat A)
Smoke density
IEC 61034
Gases corrosivity
IEC 60754-2
Electro magnetic interference resistance
Yes
Operating temperature, range
-30 ... 80 °C
Max. conductor temperature in service
90 °C
Standard
IEC
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania