TX® (I) 150/250 (300)V

Products

TX® (I) 150/250V 10x2x0.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.5 mm²
  • Minimum outer diameter: 13.0 mm
  • Nominal outer diameter: 13.9 mm
  • Maximum outer diameter: 15.5 mm
  • Approximate weight: 260 kg/km

 

TX® (I) 150/250V 10x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 16.0 mm
  • Nominal outer diameter: 16.7 mm
  • Maximum outer diameter: 18.5 mm
  • Approximate weight: 370 kg/km

 

TX® (I) 150/250V 10x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 19.5 mm
  • Nominal outer diameter: 20.6 mm
  • Maximum outer diameter: 22.5 mm
  • Approximate weight: 610 kg/km

 

TX® (I) 150/250V 10x3x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 19.0 mm
  • Nominal outer diameter: 20.0 mm
  • Maximum outer diameter: 21.5 mm
  • Approximate weight: 510 kg/km

 

TX® (I) 150/250V 14x2x0.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.5 mm²
  • Minimum outer diameter: 14.5 mm
  • Nominal outer diameter: 15.4 mm
  • Maximum outer diameter: 17.0 mm
  • Approximate weight: 340 kg/km

 

TX® (I) 150/250V 14x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 18.0 mm
  • Nominal outer diameter: 18.8 mm
  • Maximum outer diameter: 20.5 mm
  • Approximate weight: 490 kg/km

 

TX® (I) 150/250V 14x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 22.5 mm
  • Nominal outer diameter: 23.4 mm
  • Maximum outer diameter: 25.5 mm
  • Approximate weight: 820 kg/km

 

TX® (I) 150/250V 19x2x0.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.5 mm²
  • Minimum outer diameter: 17.5 mm
  • Nominal outer diameter: 18.2 mm
  • Maximum outer diameter: 20.0 mm
  • Approximate weight: 460 kg/km

 

TX® (I) 150/250V 19x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 20.5 mm
  • Nominal outer diameter: 21.6 mm
  • Maximum outer diameter: 23.5 mm
  • Approximate weight: 650 kg/km

 

TX® (I) 150/250V 19x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 27.1 mm
  • Nominal outer diameter: 26.0 mm
  • Maximum outer diameter: 29.0 mm
  • Approximate weight: 1020 kg/km

 

TX® (I) 150/250V 1x2x0.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.5 mm²
  • Minimum outer diameter: 5.4 mm
  • Nominal outer diameter: 5.7 mm
  • Maximum outer diameter: 6.6 mm
  • Approximate weight: 50 kg/km

 

TX® (I) 150/250V 1x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 6.2 mm
  • Nominal outer diameter: 6.5 mm
  • Maximum outer diameter: 7.4 mm
  • Approximate weight: 60 kg/km

 

TX® (I) 150/250V 1x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 7.4 mm
  • Nominal outer diameter: 7.7 mm
  • Maximum outer diameter: 8.6 mm
  • Approximate weight: 90 kg/km

 

TX® (I) 150/250V 1x3x0.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.5 mm²
  • Minimum outer diameter: 5.8 mm
  • Nominal outer diameter: 6.0 mm
  • Maximum outer diameter: 6.8 mm
  • Approximate weight: 50 kg/km

 

TX® (I) 150/250V 1x3x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 6.4 mm
  • Nominal outer diameter: 6.8 mm
  • Maximum outer diameter: 7.8 mm
  • Approximate weight: 70 kg/km

 

TX® (I) 150/250V 1x3x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 7.8 mm
  • Nominal outer diameter: 8.1 mm
  • Maximum outer diameter: 9.2 mm
  • Approximate weight: 100 kg/km

 

TX® (I) 150/250V 24x2x0.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.5 mm²
  • Minimum outer diameter: 19.5 mm
  • Nominal outer diameter: 20.3 mm
  • Maximum outer diameter: 22.0 mm
  • Approximate weight: 580 kg/km

 

TX® (I) 150/250V 24x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 23.5 mm
  • Nominal outer diameter: 24.5 mm
  • Maximum outer diameter: 26.5 mm
  • Approximate weight: 840 kg/km

 

TX® (I) 150/250V 2x2x0.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.5 mm²
  • Minimum outer diameter: 9.2 mm
  • Nominal outer diameter: 9.6 mm
  • Maximum outer diameter: 11.0 mm
  • Approximate weight: 90 kg/km

 

TX® (I) 150/250V 2x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 9.4 mm
  • Nominal outer diameter: 9.8 mm
  • Maximum outer diameter: 11.0 mm
  • Approximate weight: 130 kg/km

 

TX® (I) 150/250V 2x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 11.5 mm
  • Nominal outer diameter: 12.0 mm
  • Maximum outer diameter: 13.5 mm
  • Approximate weight: 190 kg/km

 

TX® (I) 150/250V 2x3x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 11.0 mm
  • Nominal outer diameter: 11.4 mm
  • Maximum outer diameter: 12.5 mm
  • Approximate weight: 160 kg/km

 

TX® (I) 150/250V 2x3x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 13.5 mm
  • Nominal outer diameter: 14.0 mm
  • Maximum outer diameter: 15.5 mm
  • Approximate weight: 260 kg/km

 

TX® (I) 150/250V 4x2x0.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.5 mm²
  • Minimum outer diameter: 9.4 mm
  • Nominal outer diameter: 9.8 mm
  • Maximum outer diameter: 11.0 mm
  • Approximate weight: 120 kg/km

 

TX® (I) 150/250V 4x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 11.0 mm
  • Nominal outer diameter: 11.4 mm
  • Maximum outer diameter: 13.0 mm
  • Approximate weight: 170 kg/km

 

TX® (I) 150/250V 4x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 13.5 mm
  • Nominal outer diameter: 14.1 mm
  • Maximum outer diameter: 15.5 mm
  • Approximate weight: 270 kg/km

 

TX® (I) 150/250V 4x3x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 12.5 mm
  • Nominal outer diameter: 13.1 mm
  • Maximum outer diameter: 14.5 mm
  • Approximate weight: 220 kg/km

 

TX® (I) 150/250V 4x3x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 15.0 mm
  • Nominal outer diameter: 15.6 mm
  • Maximum outer diameter: 17.0 mm
  • Approximate weight: 350 kg/km

 

TX® (I) 150/250V 7x2x0.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.5 mm²
  • Minimum outer diameter: 11.0 mm
  • Nominal outer diameter: 11.8 mm
  • Maximum outer diameter: 13.0 mm
  • Approximate weight: 190 kg/km

 

TX® (I) 150/250V 7x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 13.0 mm
  • Nominal outer diameter: 13.9 mm
  • Maximum outer diameter: 15.5 mm
  • Approximate weight: 260 kg/km

 

TX® (I) 150/250V 7x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 16.5 mm
  • Nominal outer diameter: 17.3 mm
  • Maximum outer diameter: 19.0 mm
  • Approximate weight: 440 kg/km

 

TX® (I) 150/250V 7x3x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 15.5 mm
  • Nominal outer diameter: 16.2 mm
  • Maximum outer diameter: 18.0 mm
  • Approximate weight: 350 kg/km

 

Description

Description

Standards

  • Product
    IEC 60228
  • Installation
    IEC 60092-350; IEC 60092-351; IEC 60092-359; IEC 60092-376
  • Test
    IEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034

Application

 

TX® (I) type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards 60092-352. TX® (I) type withstands IEC 60332-3-22 fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. 

 

Design

 

 

  1. Conductor
    Stranded Bare copper class 2
     
  2. Insulation
    XLPE (cross linked polyethylene) 
     
  3. Individual screen
    Alu/Polyester tape with a tinned copper drain wire
     
  4. Outer sheath:
    Polyolefin SHF1 (SHF2 on request)
    Colour : orange
     

Core Identification

Core 1: white + printed number

Core 2: blue + printed number

Core 3: red + printed number

 

Marking

NEXANS 448 TX (I) «voltage» «n» x 2 «or» 3 x «s» mm2 90C IEC 60332-3-22 "WW/YY" * CE *  + Metric marking

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Halogen free
IEC 60754-1
Conductor material
Bare copper
Insulation
XLPE (Cross-linked Polyethylene)
Individual screen
Aluminium / Polyester tape
Drain wire
Tinned copper
Outer sheath
Polyolefin
Sheath colour
Orange

Usage characteristics

Usage characteristics

Fire retardant
EN IEC 60332-3-22 (cat A)
Smoke density
IEC 61034
Gases corrosivity
IEC 60754-2
Electro magnetic interference resistance
Yes
Operating temperature, range
-30 ... 80 °C
Max. conductor temperature in service
90 °C
Standard
IEC

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.