TX® (I) 331 150/250 (300)V

Products

TX® ( I ) 331 150/250V 10x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 21.3 mm
  • Nominal outer diameter: 24.6 mm
  • Maximum outer diameter: 27.4 mm
  • Approximate weight: 470 kg/km

 

TX® ( I ) 331 150/250V 10x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 25.5 mm
  • Nominal outer diameter: 28.4 mm
  • Maximum outer diameter: 31.4 mm
  • Approximate weight: 700 kg/km

 

TX® ( I ) 331 150/250V 10x3x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 26.4 mm
  • Nominal outer diameter: 29.1 mm
  • Maximum outer diameter: 32.5 mm
  • Approximate weight: 660 kg/km

 

TX® ( I ) 331 150/250V 14x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 23.9 mm
  • Nominal outer diameter: 27.2 mm
  • Maximum outer diameter: 30.0 mm
  • Approximate weight: 630 kg/km

 

TX® ( I ) 331 150/250V 14x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 29.5 mm
  • Nominal outer diameter: 31.9 mm
  • Maximum outer diameter: 36.0 mm
  • Approximate weight: 950 kg/km

 

TX® ( I ) 331 150/250V 19x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 29.4 mm
  • Nominal outer diameter: 31.7 mm
  • Maximum outer diameter: 35.0 mm
  • Approximate weight: 830 kg/km

 

TX® ( I ) 331 150/250V 19x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 34.3 mm
  • Nominal outer diameter: 36.6 mm
  • Maximum outer diameter: 40.7 mm
  • Approximate weight: 1260 kg/km

 

TX® ( I ) 331 150/250V 1x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 7.8 mm
  • Nominal outer diameter: 8.4 mm
  • Maximum outer diameter: 10.0 mm
  • Approximate weight: 80 kg/km

 

TX® ( I ) 331 150/250V 1x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 9.0 mm
  • Nominal outer diameter: 9.6 mm
  • Maximum outer diameter: 11.7 mm
  • Approximate weight: 100 kg/km

 

TX® ( I ) 331 150/250V 1x3x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 8.4 mm
  • Nominal outer diameter: 9.0 mm
  • Maximum outer diameter: 10.4 mm
  • Approximate weight: 80 kg/km

 

TX® ( I ) 331 150/250V 1x3x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 9.4 mm
  • Nominal outer diameter: 10.1 mm
  • Maximum outer diameter: 11.8 mm
  • Approximate weight: 110 kg/km

 

TX® ( I ) 331 150/250V 24x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 32.6 mm
  • Nominal outer diameter: 36.7 mm
  • Maximum outer diameter: 40.0 mm
  • Approximate weight: 1060 kg/km

 

TX® ( I ) 331 150/250V 2x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 12.0 mm
  • Nominal outer diameter: 13.6 mm
  • Maximum outer diameter: 15.9 mm
  • Approximate weight: 150 kg/km

 

TX® ( I ) 331 150/250V 2x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 13.5 mm
  • Nominal outer diameter: 15.2 mm
  • Maximum outer diameter: 18.5 mm
  • Approximate weight: 220 kg/km

 

TX® ( I ) 331 150/250V 2x3x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 13.5 mm
  • Nominal outer diameter: 15.2 mm
  • Maximum outer diameter: 18.5 mm
  • Approximate weight: 210 kg/km

 

TX® ( I ) 331 150/250V 2x3x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 15.5 mm
  • Nominal outer diameter: 17.0 mm
  • Maximum outer diameter: 19.0 mm
  • Approximate weight: 300 kg/km

 

TX® ( I ) 331 150/250V 4x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 14.5 mm
  • Nominal outer diameter: 15.7 mm
  • Maximum outer diameter: 17.5 mm
  • Approximate weight: 210 kg/km

 

TX® ( I ) 331 150/250V 4x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 16.5 mm
  • Nominal outer diameter: 18.6 mm
  • Maximum outer diameter: 22.1 mm
  • Approximate weight: 310 kg/km

 

TX® ( I ) 331 150/250V 4x3x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 16.5 mm
  • Nominal outer diameter: 17.8 mm
  • Maximum outer diameter: 20.5 mm
  • Approximate weight: 270 kg/km

 

TX® ( I ) 331 150/250V 4x3x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 18.5 mm
  • Nominal outer diameter: 20.3 mm
  • Maximum outer diameter: 22.4 mm
  • Approximate weight: 410 kg/km

 

TX® ( I ) 331 150/250V 7x2x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 18.0 mm
  • Nominal outer diameter: 19.5 mm
  • Maximum outer diameter: 22.3 mm
  • Approximate weight: 340 kg/km

 

TX® ( I ) 331 150/250V 7x2x1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 21.1 mm
  • Nominal outer diameter: 22.8 mm
  • Maximum outer diameter: 25.6 mm
  • Approximate weight: 500 kg/km

 

TX® ( I ) 331 150/250V 7x3x0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 20.2 mm
  • Nominal outer diameter: 22.5 mm
  • Maximum outer diameter: 26.0 mm
  • Approximate weight: 450 kg/km

 

Description

Description

Standards

  • Product
    IEC 60228
  • Installation
    IEC 60092-350; IEC 60092-351; IEC 60092-359; IEC 60092-376
  • Test
    IEC 60331-1 or 2; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034

Application

TX® (I) 331 type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards 60092-352. TX® (I) 331 type meets IEC 60331 fire resistant performances, withstands IEC 60332-3-22 fire test on bunched cables and peforms to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire.

Design

 

1. Conductor:

        Bare copper

        Stranded class 2

2.  Insulation:

         Mica+XLPE

3.  Individual screen:

         Alu/Polyester tape with a tinned copper drain wire

4.  Outer sheath:

         Polyolefin SHF1 (SHF2 on request)

         Colour: orange

Core Identification

         Core 1: white + printed number

         Core 2: blue + printed number

         Core 3: red + printed number

Marking

NEXANS 448 TX (I) 331 «voltage» «n» x 2 «or» 3 x «s» mm2 90C IEC 60332-3-22 IEC 60331 «WW/YY» * * + Metric Marking

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Halogen free
IEC 60754-1
Conductor material
Bare copper
Insulation
HFFR special
Screen
Aluminium-Polyester tape
Drain wire
Tinned copper
Outer sheath
Polyolefin
Sheath colour
Orange

Usage characteristics

Usage characteristics

Fire resistant
IEC 60331-21
Fire retardant
EN IEC 60332-3-22 (cat A)
Smoke density
IEC 61034
Gases corrosivity
IEC 60754-2
Electro magnetic interference resistance
Yes
Operating temperature, range
-30 ... 80 °C
Max. conductor temperature in service
90 °C
Standard
IEC

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close