MPRX-FLEX 0.6/1 (1.2) kV

Products

MPRX-FLEX 0.6/1kV 1 x 120

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 120 mm²
  • Maximum outer diameter: 24.5 mm
  • Approximate weight: 1290 kg/km
  • Permissible current rating in open air: 339 A

 

MPRX-FLEX 0.6/1kV 1 x 150

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 150 mm²
  • Maximum outer diameter: 26.5 mm
  • Approximate weight: 1600 kg/km
  • Permissible current rating in open air: 389 A

 

MPRX-FLEX 0.6/1kV 1 x 185

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 185 mm²
  • Maximum outer diameter: 28.5 mm
  • Approximate weight: 1960 kg/km
  • Permissible current rating in open air: 444 A

 

MPRX-FLEX 0.6/1kV 1 x 240

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 240 mm²
  • Maximum outer diameter: 32.0 mm
  • Approximate weight: 2510 kg/km
  • Permissible current rating in open air: 522 A

 

MPRX-FLEX 0.6/1kV 1 x 95

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 95 mm²
  • Maximum outer diameter: 21.0 mm
  • Approximate weight: 1030 kg/km
  • Permissible current rating in open air: 293 A

 

MPRX-FLEX 0.6/1kV 3 x 120

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 120 mm²
  • Maximum outer diameter: 50.0 mm
  • Approximate weight: 4200 kg/km
  • Permissible current rating in open air: 237 A

 

MPRX-FLEX 0.6/1kV 3 x 50

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 50 mm²
  • Maximum outer diameter: 33.5 mm
  • Approximate weight: 1850 kg/km
  • Permissible current rating in open air: 137 A

 

MPRX-FLEX 0.6/1kV 3 x 70

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 70 mm²
  • Maximum outer diameter: 38.0 mm
  • Approximate weight: 2530 kg/km
  • Permissible current rating in open air: 169 A

 

MPRX-FLEX 0.6/1kV 3 x 95

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 3
  • Conductor cross-section: 95 mm²
  • Maximum outer diameter: 43.0 mm
  • Approximate weight: 3330 kg/km
  • Permissible current rating in open air: 205 A

 

MPRX-FLEX 0.6/1kV 1 x 70

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 70 mm²
  • Maximum outer diameter: 19.0 mm
  • Approximate weight: 780 kg/km
  • Permissible current rating in open air: 242 A

 

Description

Description

Standards

  • Product
    IEC 60228
  • Installation
    IEC 60092-350; IEC 60092-351; IEC 60092-353; IEC 60092-359
  • Test
    IEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034

Application

MPRX®-FLEX type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards 60092-352. MPRX-FLEX using is recommended for installations in narrow space. MPRX®-FLEX type withstands IEC 60332-3-22 fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. 

 

Design
 

  1. Conductor
    Flexible Bare copper class 5 
     
  2. Insulation
    XLPE (cross linked polyethylene) 
     
  3. Outer sheath:
    Filler if necessary
    Polyolefin SHF1 (SHF2 on request)
    Colour : black

Core Identification

1 cores: black

2 cores: black-blue

3 cores: black-white-brown or black-blue-green/yellow

4 cores: black-white-brown-blue or green/yellow

5 cores and above: white with black printed numbers

Marking

NEXANS 448 MPRX-FLEX 0.6/1 kV «n» x «s» mm2 90C IEC 60332-3-22 «WW/YY» * CE * + Metric Marking

Characteristics

Characteristics

Construction characteristics

Construction characteristics

With Green/Yellow core
No

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Very flexible

Usage characteristics

Usage characteristics

Standard
IEC
Gases corrosivity
IEC 60754-2
Fire retardant
EN IEC 60332-3-22 (cat A)
Flame retardant
IEC 60332-1
Operating temperature, range
-30 ... 80 °C
Max. conductor temperature in service
90 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close