TX(C) 331 150/250V 10x2x0.75
Description
Description
Standards
-
ProductIEC 60228
-
InstallationIEC 60092-350; IEC 60092-351; IEC 60092-359; IEC 60092-376
-
TestIEC 60331; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Application
TX® (C) 331 type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards 60092-352.TX® (C)331 type meets 60331 fire resistant performances, withstands IEC 60332-3-22 fire test on bunched cables and peforms to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire.
Design
- Conductor:
Bare copper
Stranded class 2
- Insulation:
Mica tape + XLPE
- Collective screen:
Alu/Polyester tape with a tinned copper drain wire
- Outer sheath:
Polyolefin SHF1
Colour: orange
SHF2 on request
*Note: 2 pairs assembled as a quad
Core Identification
Core 1: white + printed number
Core 2: blue + printed number
Core 3: red + printed number
Marking
NEXANS 448 TX (C) 331 «voltage» «n» x 2 «or» 3 x «s» mm2 90C IEC 60332-3-22 IEC-60331 «WW/YY» * * + Metric Marking