MOTIONLINE® PREMIUM HYBRID CABLES ACC. TO SICK HIPERFACE DSL® STANDARD PUR
MOTIONLINE® PREMIUM HYBRID CABLES ACC. TO SICK HIPERFACE DSL® STANDARD PUR
For extremely dynamic application MOTIONLINE® PREMIUM
Mehr lesenBeschreibung
Beschreibung
Normen
-
ProduktUL and CSA approval
Hybrid cables for servo motors for extremely dynamic applications; PUR Jacket; screened, resistant to oils and coolants, notch resistant, flame retardant, resistant to hydrolysis and microbes, PVC- and halogen-free.
Design
Conductor
Bare copper
Core insulation
Polyolefine
Core stranding
Power cores & control pairs stranded with fillers
Core identification
DSL: Blue - White
Signal: Black num.
5 + Black num. 6
Power: Black num.
1-3 + Y/G
Screen
Overall screen:
Tinned copper braid,
coverage ≥ 85%
Signal screen:
Tinned copper braid,
coverage ≥85%
Jacket
PUR
Colour: Orange
(similiar RAL 2003)
Eigenschaften
Eigenschaften
Konstruktionsmerkmale
Konstruktionsmerkmale
Leitungsaufbau
(4G0.5+(2x0.35)C+(2xAWG26)C)C
Leitermaterial
Kupfer, blank
Isolierung
Polypropylene
Isolationsfarbe
DSL: Blue-White; Signal: Black num. 5 + Black num. 6; Power: Black num. 1-3 + Y/G
Verseilung
Leistungsadern mit Steueradern und Füllern verseilt
Schirmung
Verzinntes Kupfergeflecht, Bedeckung ≥ 85%
Außenmantel
PUR
Mantelfarbe
Orange RAL 2003
Halogenfrei
Ja
Abmessungsmerkmale
Abmessungsmerkmale
Aussendurchmesser
- mm
Kupferzahl
- kg/km
Nettogewicht ca.
134 kg/km
Elektrische Eigenschaften
Elektrische Eigenschaften
Rated Voltage Uo/U
0.6/1 kV
Prüfspannung
4000 V
Mechanische Eigenschaften
Mechanische Eigenschaften
Biegezyklen
10 Mio.
Verfahrgeschwindigkeit
300 m/min
maximale Beschleunigung
50 m/s²
Anwendungsmerkmale
Anwendungsmerkmale
Einsatzbereich
Dynamic
Minimaler Biegeradius bewegt
7,5 (xD)
Betriebstemperatur
-30 ... 80 °C
Lagertemperatur, Bereich
-50 ... 80 °C
Ölbeständig
EN 50363-10-2
Flammwidrig
IEC/EN 60332-1-2; FT1; UL 1581 FT1
Silikonfrei
ja