- Produkte
- Unsere Lösungen
- Unternehmen
- Presse
- Tools und Ressourcen
- Suchen
- Kontaktieren Sie uns
- Vergleichen
- Anmelden
ENERGYFLEX - TÜV zertifiziert
ENERGYFLEX - TÜV zertifiziert
ENERGYFLEX
Energyflex® cables are designed to comply with the international standards of the solar plants.
They are dedicated to the photovoltaic system direct current (D.C.) side with a nominal D.C. voltage of 1.5 kV and a maximum D.C. voltage of 1.8 kV. These cables are suitable for permanent outdoor long-term use, under variable and harsh climate conditions.
They are designed and tested to operate at a normal maximum conductor temperature of 90°C and for 20,000 hours up to 120°C. Therefore, the expected period use is 30 to 40 years under normal usage conditions (lifetime acc. to Arrhenius-Diagram).
- Produkt ref. : 10189495
- EAN : 3427640020217
Beschreibung
Beschreibung
Normen
-
ProduktEN 50618; IEC 62930
DESIGN
Single core fire resistance solar cable with low smoke, halogen free, crosslinked insulation and sheath.
1. Conductor
Stranded tinned copper wires class 5 acc. IEC 60228
2. Insulation
Cross-linked halogen-free rubber
Colour: white
3. Sheath
Cross-linked halogen-free fire retardant rubber
Colour: black
Example of marking: ENERGYFLEX® USE < HAR > H1Z2Z2-K 62930 IEC 131 1 x S mm² 1.5/1.5 (1,8) kV DC lynxeo 269 MADE IN FRANCE Dca
FEATURES
ENERGYFLEX® cables are dedicated to the photovoltaic system direct current (D.C.) side with a nominal D.C. voltage of 1.5 kV and a maximum D.C. voltage of 1.8 kV. Cable suitable to be used with Class II equipment.
These cables are suitable for permanent outdoor long-term use, under variable and harsh climate conditions. They are designed and tested to operate at a normal maximum conductor temperature of 90°C and for 20,000 hours up to 120°C. Therefore, the expected period use is 30 to 40 years under normal usage conditions (lifetime acc. to Arrhenius Diagram).
ENERGYFLEX® cables have a suitable behaviour in water : tests of Annexes D and E of H07RN8F AD8 cables (100 days at 50 °C under 1 kV AC without breakdown), and additional test of 1,5 year in hot water (85°C) under 1 kV DC without breakdown. They are suitable for submerged installations with a maximum cumulated immersion period of 4 months / year.
Eigenschaften
Eigenschaften
Konstruktionsmerkmale
Konstruktionsmerkmale
Abmessungsmerkmale
Abmessungsmerkmale
Elektrische Eigenschaften
Elektrische Eigenschaften
Mechanische Eigenschaften
Mechanische Eigenschaften
Anwendungsmerkmale
Anwendungsmerkmale
Ressourcen
Ressourcen
Dokumentation
Leistungserklärung
- Leistungserklärung Nr (DoP) : 1000199-FRAN
- Datum der Zertifizierung : 17.12.19
- AVCP (Assessment and Verification of Constancy of Performance) : System 3
- Benachrichtigte Stelle : NB 1812
- Erklärte Leistung : Dca-s2,d2,a1