MLA 22 004
MLA 22 004
Designed for general Purpose Aircraft Wiring Applications.
260°C, Screened and Jacketed,
Light Weight, UV cable,
Arc tracking Resistant
- Produkt ref. : EN 2714-013A 004F (MLA22)
- Land ref. : 10062816
Beschreibung
Beschreibung
Normen
-
ProduktEN 2267-009; EN 2714-013
DESIGN CONSTRUCTION
CORES
1 cores
EN2267-009A
SCREEN
Nickel plated copper spiral screen
JACKET
Polyimide tape
UV PTFE tape
CORES
2, 3 or 4 cores
EN2267-009A
SCREEN
Nickel plated copper spiral screen
JACKET
Polyimide tape
UV PTFE tap
IDENTIFICATION
| IDENTIFICATION | |
| 1 core (MLB) | : white execpt code 001: Light Yellow/ code 004: Light Green |
| : | |
| Marking | : EN DRA ++ FRF ** |
| Colour of marking | : White for red and green core, |
| Green for blue and yellow core | |
| Jacket | |
| Colour | : White except code 002, 006, 012 : Light Blue |
| Marking | : EN xxx ++ FRF ** |
| Colour of marking | : Green |
| xxx : Short designation (MLA, MLB, MLC, MLD) | |
| ++ : AWG | |
| FR : Country of Origin (FR = France) | |
| F : Manufacturer (F = Lynxeo) | |
| ** : Year of manufacturing (ie 14 = 2014 |
New Free Section - 103114
Eigenschaften
Eigenschaften
Konstruktionsmerkmale
Konstruktionsmerkmale
Aderkennzeichnung
Light green
Anzahl Leiter
1
Farbe
-
Jacket color
White
Jacket material
Polyimide tape, UV PTFE tape
Mantelfarbe
-
Schirm
Nickel plated copper spiral screen
Abmessungsmerkmale
Abmessungsmerkmale
Nennaussendurchmesser
1,5 inches
Maximaler Außendurchmesser
1,6 mm
Abmessung (AWG)
22
Aderanzahl
1
Screen strands nominal diameter
0,08 mm
Max. Gewicht
7,51 g/m
Nominal weight
6,97 g/m
Elektrische Eigenschaften
Elektrische Eigenschaften
Maximale Betriebsfrequenz
0,002 MHz
Maximum DC resistance at 20°C
60 Ohm/100m
Betriebsspannung Vo DC
28 V
Operating voltage between phases
200 V
Operating voltage between phase and neutral
115 V
Anwendungsmerkmale
Anwendungsmerkmale
Ölbeständig
Very good resistance to aircraft fluids
Arc tracking resistant
Ja
RoHS konform
ja
Betriebstemperatur
-55 ... 260 °C