ENERGYFLEX PV H1Z2Z2-K (1.5kV DC)

Products

PV H1Z2Z2-K Energyflex 1x4mm² NR

Product ref. 10189494

  • Packaging: Drum (m)
  • Conductor cross-section: 4 mm²
  • Approximate weight: 62 kg/km
  • Nominal conductor diameter: 2.5 mm
  • Max. DC resistance of the conductor at 20°C: 5.09 Ohm/km
  • Permissible current rating in air 60°C: 55 A
  • Permissible current rating on a tray 60°C: 52 A
  • Permissible short circuit current conductor 1s: 0.5 kA

 

PV H1Z2Z2-K Energyflex 1x6mm² NR

Product ref. 10189495

  • Packaging: Drum (m)
  • Conductor cross-section: 6 mm²
  • Approximate weight: 80 kg/km
  • Nominal conductor diameter: 2.9 mm
  • Max. DC resistance of the conductor at 20°C: 3.39 Ohm/km
  • Permissible current rating in air 60°C: 70 A
  • Permissible current rating on a tray 60°C: 67 A
  • Permissible short circuit current conductor 1s: 0.8 kA

 

PV H1Z2Z2-K Energyflex 1x10mm² NR

Product ref. 10191044

  • Packaging: Drum (m)
  • Conductor cross-section: 10 mm²
  • Approximate weight: 127 kg/km
  • Nominal conductor diameter: 4 mm
  • Max. DC resistance of the conductor at 20°C: 1.95 Ohm/km
  • Permissible current rating in air 60°C: 98 A
  • Permissible current rating on a tray 60°C: 93 A
  • Permissible short circuit current conductor 1s: 1.3 kA

 

Description

Description

Standards

  • Product
    EN 50618; IEC 62930

DESIGN

Single core fire resistance solar cable with low smoke, halogen free, crosslinked insulation and sheath.

1. Conductor
   Stranded tinned copper wires class 5 acc. IEC 60228

2. Insulation
   Cross-linked halogen-free rubber
   Colour: white

3. Sheath
   Cross-linked halogen-free fire retardant rubber
   Colour: black

Example of marking: ENERGYFLEX® USE < HAR > H1Z2Z2-K 62930 IEC 131 1 x S mm² 1.5/1.5 (1,8) kV DC lynxeo 269 MADE IN FRANCE Dca

FEATURES

ENERGYFLEX® cables are dedicated to the photovoltaic system direct current (D.C.) side with a nominal D.C. voltage of 1.5 kV and a maximum D.C. voltage of 1.8 kV. Cable suitable to be used with Class II equipment.

These cables are suitable for permanent outdoor long-term use, under variable and harsh climate conditions. They are designed and tested to operate at a normal maximum conductor temperature of 90°C and for 20,000 hours up to 120°C. Therefore, the expected period use is 30 to 40 years under normal usage conditions (lifetime acc. to Arrhenius Diagram).

ENERGYFLEX® cables have a suitable behaviour in water : tests of Annexes D and E of H07RN8F AD8 cables (100 days at 50 °C under 1 kV AC without breakdown), and additional test of 1,5 year in hot water (85°C) under 1 kV DC without breakdown. They are suitable for submerged installations with a maximum cumulated immersion period of 4 months / year.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Halogen free
IEC 60754-1; IEC 60754-2

Dimensional characteristics

Dimensional characteristics

Number of cores
1

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
1.0/1.0 (1.2) kV AC 1.5/1.5 (1.8) kV DC

Usage characteristics

Usage characteristics

Operating temperature, range
-40 ... 90 °C
Packaging
Drum
Gases corrosivity
IEC 60754-2
Smoke density
IEC 61034-1-2
Ozone resistance
EN 50396
Weather resistance
Excellent
Flame retardant
IEC 60332-1
Fire retardant
EN 50575
Maximum operating temperature
120 °C
U.V resistance
EN 50289-4-17 method A, for 720h. Nexans prestige test 4000h
Water proof
Passed 100 days 50°C water immersion test of EN 50525-2-21 annex D and E

Resources

Resources

Documentation

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close