STUDY 69794 - EN 3375-004C WJ
STUDY 69794 - EN 3375-004C WJ
Data bus cable for multiplexed transmission.
77 Ohms, AWG 24 - Pair Double Shielded - High Temperature
Description
Description
Normes
-
ProduitEN 3375-004
CORE
AWG 24, 19 x 0.12 mm
Silver plated high strength copper alloy
Fluoropolymer insulation
ASSEMBLY
2 cores twisted with 2 fillers
SHIELD
2 Silver plated copper braid
Strand diameter : 0.10 mm
JACKET
Fluoropolymer
Electrical and high frequency performances
Voltage rating | : 600V AC |
Characteristic impedance | : 77 ± 7 Ω |
Maximum capacitance | : 78 pF/m |
Maximum attenuation | : 3.6 dB/100m at 1 MHz |
Maximum transfer impedance | : 15 mΩ/m DC |
: 5 mΩ/m at 1 MHz | |
: 5 mΩ/m at 10 MHz | |
: 10 mΩ/m at 30 MHz |
Identification
Colour of cores | : Blue + White |
Colour of jacket |
: White Jacket code 'none': . Colour of marking : Green. Jacket code '01': . Colour of marking : Red for the main line. Jacket code '02': . Colour of marking : Blue for the branch line.
Marking text : FILOTEX FRANCE ET 69794-** (**) Year of manufacturing |
Caractéristiques
Caractéristiques
Caractéristiques d'utilisation
Caractéristiques d'utilisation
Température ambiante d'utilisation, plage
-65 ... 200 °C
Rayon de courbure minimum en utilisation statique
26 mm
Non propagateur de la flamme
FAR/JAR part 25 sec 25.869 (a)(4) Appendix F part 1 (3)