(N)HXCSLOE-JZ 5x2,5
Description
Description
Standards
-
ProductEN 50363; HD 22-13; IEC 60228; IEC 60502
Applications
Low voltage loop cable WINDLINK LV-RS (N)HXSLOE was developed for special application conditions in wind turbines. The construction is torsion resistant by free hanging of max. 100 m. These cables are specified for medium mechanical stress and for operation under permanent influence of sea water and usage outdoor.
Resistance to
- permanent movement
- permanent vibrations
- compressive stress
- oil, EN60811-2-1, ASTM No.2, 24h at 100°C
- low smoke, IEC 61034, >50 %
- halogen-free IEC 60754
- permanent influence of sea water
- ozone influence, EN 60811-2-1 clause 8
- suitable for torsion of max. 6 counterclockwise rotations and min. free hanging up from 25 m
Design
Core
Conductor
- Copper, plain, flexible concentrically stranded circular
Insulation
- Extruded halogen-free rubber compound EI8 acc. to EN 50363-5
Outer Sheath
- Extruded halogen-free EVA compound EM8 acc. to EN 50363-6
Characteristics
Characteristics
结构特性
结构特性
导体材料
Plain annealed copper
导线柔软度
柔软等级5
绝缘
无卤复合物
外护套
橡胶复合物
护套颜色
黑
无卤
IEC 60754-2
总屏蔽
-
有绿/黄芯线
是
尺寸特性
尺寸特性
芯线数
5
导线截面
2.5 mm²
铜含量
0 kg/km
标称外径
15.0 mm
近似重量
300 kg/km
电气特性
电气特性
额定电压Uo/U
0.6 / 1 kV
使用特性
使用特性
阻燃 - 火焰
EN 50265-2-1
无硅
是
符合RoHS
是
芯线最高静止温度
90 °C
耐气候性
优异
短路最高线芯温度
250 °C
Resources
Resources
Documentation
UL certificate
pdf — 676.6 kB
Selling & delivery Information
Inkjet marking e.g.: WINDLINK LV-RS (N)HXSLOE 0.6/1 kV I NEXANS I
我们的网站
选择你的国家查找我们的产品和解决方案
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania