WINDLINK® LV-RS (N)HXCMFOE
0.6/1 kV
WINDLINK® LV-RS (N)HXCMFOE
0.6/1 kV
Torsion resistant low-voltage loop cable for free hanging of max. 100 m
Screeened cables acc. to EN 50525-2-21 and EN 50125-3-21
1x95 RF
Product ref.
- 包装: Drum (1000米)
- 导线截面: 95 mm²
- 外径最小值: 20.8 mm
- Maximum outer diameter: 21.8 mm
- 近似重量: 1200 kg/km
1x120 RF
Product ref.
- 包装: Drum (1000米)
- 导线截面: 120 mm²
- 外径最小值: 22.7 mm
- Maximum outer diameter: 24.7 mm
- 近似重量: 1500 kg/km
1x150 RF
Product ref.
- 包装: Drum (1000米)
- 导线截面: 150 mm²
- 外径最小值: 25.2 mm
- Maximum outer diameter: 27.2 mm
- 近似重量: 1700 kg/km
1x185 RF
Product ref.
- 包装: Drum (1000米)
- 导线截面: 185 mm²
- 外径最小值: 27.9 mm
- Maximum outer diameter: 30.9 mm
- 近似重量: 2100 kg/km
1x240 RF
Product ref.
- 包装: Drum (1000米)
- 导线截面: 240 mm²
- 外径最小值: 31.1 mm
- Maximum outer diameter: 33.1 mm
- 近似重量: 2700 kg/km
1x300 RF
Product ref.
- 包装: Drum (1000米)
- 导线截面: 300 mm²
- 外径最小值: 33.5 mm
- Maximum outer diameter: 35.5 mm
- 近似重量: 3400 kg/km
Description
Description
Standards
-
ProductEN 50525-2-21; EN 50264; EN 50363; IEC 60502
Application
Low-voltage loop cable WINDLINK® LV-RS (N)HXCMFOE in two sheath design was developed for special application condition in windturbines. The construction is torsion resistant by free hanging max. 100 m. These cables are specified for medium mechanical stress and for operation under permanent influence of seawater and usage outdoor.
Resistance to:
- Permanent movement
- Permanent vibrations
- Compressive stress
- Oil
- Leach
- Flame-retardant
- Permanent influence of seawater
- Weather
- UV
- Ozone influence, suitable for moving outdoor
- Suitable for torsion up to +/- 80°/meter, test 2,000 cycles
Design
1. Conductor
Copper, plain, flexible stranded, class 5 acc. to DIN EN 60228
2. Insulation
Special EPR thermosetting compound
3. Screen
Tinned wire copper braid, covering min.80%
4. Outer Sheath
Special EVA thermosetting compound, ozone- and UV-resistant, oil-resistant,
colour: black
Operating condition
| Temperatures | moved transport and stock operating temperature at conductor short circuit teperature at conductor |
-40+ 90 °C -40/+90 °C 90 °C 250°C |
| Max. tensile load | short time, e.g.speed up N/mm² in operation |
50 15 |
| Bending radii | fixed free moving Inlet ant strain relief |
³ 3 x D ³ 5 x D ³ 5 x D (D = cable diameter) |
| Torsion | max. permissible angle | ± 80 °/m |
Characteristics
Characteristics
结构特性
结构特性
尺寸特性
尺寸特性
电气特性
电气特性
使用特性
使用特性
Resources
Resources
Documentation
Selling & delivery Information
Inkjet marking e.g.: WINDLINK® LV-RS (N)HXMCFOE 1x95 0.6/1 kV I NEXANS I