FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x70
FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x70
FLAMEX
FIRE RESISTANT POWER CABLES
FLAMEX® EN50264-3-1 FR flexible power cables maintain circuit integrity in case of fire (according to EN 50200 for 90 minutes) and are fire retardant, low smoke and halogen-free safisfying performance requirements of EN 45545-2-HL3. On top of that, FLAMEX® cables withstand tough working conditions (oil, ozone, temperature variations, etc.).
- Nexans ref. : 79463214
Description
Description
Standards
-
ProductEN 50264-3-1; EN 45545 - HL3; IEC 60228
-
TestEN 50200; IEC 60331-1 or 2
FLAMEX® EN50264-3-1 FR flexible power cables maintain circuit integrity in case of fire (according to EN 50200 for 90 minutes) and are fire retardant, low smoke and halogen-free safisfying performance requirements of EN 45545-2-HL3. On top of that, FLAMEX® cables withstand tough working conditions (oil, ozone, temperature variations, etc.).
DESIGN
1. Conductor
Flexible stranded tinned copper, class 5 acc. to IEC 60228
Mineral tape
2. Insulation
Cross-linked compound type EI 109 acc. to EN 50264-1
Oil, diesel, ozone and UV resistant
Colour: black
Example of marking: FLAMEX type EN 50264-3-1 FR 600 V mm² M (N)MHXAF-FR 0,6/1kV
I LYNXEO I WW-YYYY
FIRE SAFETY
FLAMEX® FR TYPE EN 50264-3-1 power cables are conform to EN 45545-2 HL3
Fire resistant according to EN 50200 / IEC 60331-1 or -2
GUIDE TO USE
- Cabling rules are given in EN 50343 and EN 50355
- Permissible current carrying capacities: values and calculation method are given in EN 50343
- Bending radius:
- Static use: 3 x outer cable diameter if D ≤ 10mm / 5 x outer cable diameter if D > 10mm
- For installation and occasional movements: 10 x outer cable diameter