FLAMEX 20 TYPE MSZ 1X0.75
FLAMEX 20 TYPE MSZ 1X0.75
FLAMEX
FIRE RESISTANT CONTROL WIRES
FLAMEX® Fire Resistant control wires TYPE EN 50306-2 maintain circuit integrity in case of fire (according to EN 50200 for 120 minutes) and are fire retardant, low smoke and halogenfree safisfying performance requirements of EN 45545-2 HL3. In addition, FLAMEX® cables withstand the tough working conditions of rolling stock (oil, ozone, temperature variations, etc.).
- Nexans ref. : 13112324
- Country ref. : 2PN300
Description
Description
Standards
-
ProductEN 45545-2 (HL3)
-
TestEN 50200; EN 50305; EN 50306; IEC 60331-2
FLAMEX® Fire Resistant control wires TYPE EN 50306-2 maintain circuit integrity in case of fire (according to EN 50200 for 120 minutes) and are fire retardant, low smoke and halogenfree safisfying performance requirements of EN 45545-2 HL3. In addition, FLAMEX® cables withstand the tough working conditions of rolling stock (oil, ozone, temperature variations, etc.).
DESIGN
1. Conductor
Flexible stranded tinned copper
2. Insulation
Mineral tape as fire barrier
Thin wall halogen-free cross-linked material acc. EN 50306-2
Colour: white
Example of marking: FLAMEX 239 - EDE 2PN299 - TYPE EN 50306-2 - EN 50200 - 300 V - 1x0.5 - M - week/year - batch number
FIRE SAFETY STANDARDS
FLAMEX® Fire Resistant control wires are conform to EN 45545-2.
GUIDE TO USE
- Cabling rules are given in EN 50343 and EN 50355
- Permissible current carrying capacities: values and calculation method are given in EN 50343
- Bending radius:
- Static use: 5 x outer cable diameter
- For installation and occasional movements: 10 x outer cable diameter