- Produkte
- Unsere Lösungen
- Unternehmen
- Presse
- Tools und Ressourcen
- Suchen
- Kontaktieren Sie uns
- Vergleichen
- Anmelden
ENERGYFLEX PV H1Z2Z2-K (1.5kV DC)
ENERGYFLEX PV H1Z2Z2-K (1.5kV DC)
ENERGYFLEX
Energyflex® cables are designed to comply with the international standards of the solar plants. They are dedicated to the photovoltaic system direct current (D.C.) side with a nominal D.C. voltage of 1.5 kV and a maximum D.C. voltage of 1.8 kV.
ENERGYFLEX - TÜV zertifiziert
Produkt ref. 10189494
- Verpackung: Trommel (m)
- Leiterquerschnitt: 4 mm²
- Nettogewicht ca.: 62 kg/km
- Nominal conductor diameter: 2,5 mm
- Max. Gleichstromwiderstand des Leiters bei 20° C: 5,09 Ohm/km
- Kurzschlussstrom Leiter 1s: 0,5 kA
- Permissible current rating in air 60°C: 55 A
- Permissible current rating on a tray 60°C: 52 A
ENERGYFLEX - TÜV zertifiziert
Produkt ref. 10189495
- Verpackung: Trommel (m)
- Leiterquerschnitt: 6 mm²
- Nettogewicht ca.: 80 kg/km
- Nominal conductor diameter: 2,9 mm
- Max. Gleichstromwiderstand des Leiters bei 20° C: 3,39 Ohm/km
- Kurzschlussstrom Leiter 1s: 0,8 kA
- Permissible current rating in air 60°C: 70 A
- Permissible current rating on a tray 60°C: 67 A
ENERGYFLEX - TÜV zertifiziert
Produkt ref. 10191044
- Verpackung: Trommel (m)
- Leiterquerschnitt: 10 mm²
- Nettogewicht ca.: 127 kg/km
- Nominal conductor diameter: 4 mm
- Max. Gleichstromwiderstand des Leiters bei 20° C: 1,95 Ohm/km
- Kurzschlussstrom Leiter 1s: 1,3 kA
- Permissible current rating in air 60°C: 98 A
- Permissible current rating on a tray 60°C: 93 A
Beschreibung
Beschreibung
Normen
-
ProduktEN 50618; IEC 62930
DESIGN
Single core fire resistance solar cable with low smoke, halogen free, crosslinked insulation and sheath.
1. Conductor
Stranded tinned copper wires class 5 acc. IEC 60228
2. Insulation
Cross-linked halogen-free rubber
Colour: white
3. Sheath
Cross-linked halogen-free fire retardant rubber
Colour: black
Example of marking: ENERGYFLEX® USE < HAR > H1Z2Z2-K 62930 IEC 131 1 x S mm² 1.5/1.5 (1,8) kV DC lynxeo 269 MADE IN FRANCE Dca
FEATURES
ENERGYFLEX® cables are dedicated to the photovoltaic system direct current (D.C.) side with a nominal D.C. voltage of 1.5 kV and a maximum D.C. voltage of 1.8 kV. Cable suitable to be used with Class II equipment.
These cables are suitable for permanent outdoor long-term use, under variable and harsh climate conditions. They are designed and tested to operate at a normal maximum conductor temperature of 90°C and for 20,000 hours up to 120°C. Therefore, the expected period use is 30 to 40 years under normal usage conditions (lifetime acc. to Arrhenius Diagram).
ENERGYFLEX® cables have a suitable behaviour in water : tests of Annexes D and E of H07RN8F AD8 cables (100 days at 50 °C under 1 kV AC without breakdown), and additional test of 1,5 year in hot water (85°C) under 1 kV DC without breakdown. They are suitable for submerged installations with a maximum cumulated immersion period of 4 months / year.